Temperature difference measurement, Sensor break monitoring, Action – KROHNE OPTITEMP TT 31 R EN User Manual
Page 21
Advertising

02/2011 – 4000753501 – MA OPTITEMP TT31CR R01 en
www.krohne.com
21
5.2.1
Temperature difference measurement
The sensor break function must be deactivated for temperature difference
measurements.
In the "Temp Soft" software, the sensor break function must be set to
"Sensor break = without".
5.2.2
Sensor break monitoring
The transmitter uses a pulse signal to determine a sensor break/short circuit. This signal
may interfere with electronic temperature calibrators. To switch off the pulse signal,
deactivate the "Sensor break" function (Sensor break = without) in the "TempSoft"
software.
Action
To protect the PC connections, they must be closed off using the supplied protection
caps after configuration has been completed.