KROHNE ALTOFLUX IFM 5080 K EEx EN User Manual
Page 4

4
With each in/output module a certain in/output function can be realised, see following overview:
In/Output
module
Function
Electrical data
P-SA
passive current output
Current:
4..20 mA
Working voltage:
8.. 30 V DC
Voltage drop:
8 V at 4 mA
FA-ST
passive pulse/status output or
control input (selectable through
software options)
Working voltage:
6..30 V DC
Working current:
< 110 mA
Voltage drop
in ON-state:
< 2 V at 110 mA
Leakage current
in OFF-state:
< 900
µ
A at 30 V
Control input
Input voltage LOW level:
< 3 V
Input voltage HIGH level:
> 7 V
Frequency range:
0.. 12 KHz
DC-I
intrinsically safe voltage source,
to be used in combination with
modules P-SA and FA-ST
Voltage:
20 V DC
Maximum current:
30 mA
Internal resistance:
260
Ω
F-PA
passive Fieldbus interface
conform FISCO model
Connection power supply
(non-intrinsically safe)
Connection of signal-in/outputs
(intrinsically safe)