Part a system installation and start-up – KROHNE VFM 1091 User Manual

Page 4

Advertising
background image

4

KRONHE MARSHALL vortex flowmeters operate on the Karman
vortex street principle to measure volumetric flow rate of gases /steam
and liquids. VFM 1091 computes normalized volumetric and mass flow
rates from operating & normalized density values supplied through
operator interface.

Items included with shipment for Compact flowmeter

•

Compact Vortex flowmeter and operating instructions

•

Installation and Operating Instructions

•

Mounting bolts, washers, nuts

•

Programming chart indicating factory configuration setting

•

Optional upstream and downstream pipes

•

Gaskets between primary head & pipeline

Items included with shipment for field mounted
Flowmeter

•

Field mounted sensor VFS 1091 F

•

Pipe/Wall mounted separated signal converter VFC 091F

•

Connecting Cable (10m) between VFS 1091 F & VFC 091F

•

Installation and Operating Instructions

•

Mounting bolts, washers, nuts

•

Programming chart indicating factory setting.

Provided by customer

•

All cables for electrical connections.

1. Flow direction and meter position -

•

Flow must always be in the direction of the arrow, bluff side of

vortex-shedding body facing incoming flow i.e. upstream side.

•

Vertical pipe run: upward flow direction

•

Horizontal pipe run: see below

2. Difference between inside diameters of primary head and

pipeline

D

Ν

Meter size of primary head in millimeters or Inches

Φ

Inside diameter of primary head in millimeters Max.

∆Φ

allowable difference between inside
diameters of primary head and pipeline

Ensure that the bore of upstream and down-stream pipes are smooth
and without deposits or scaling of welding beads.

3. Straight, unimpeded inlet and outlet runs
D = Meter size (Nominal Dia. DN)

CONTROL VALVE

BALL/GATE VALVE
(FULLY OPEN)

2 X 90

0

BENDS

3-DIMENSIONAL
(SAME FOR 3 X 90

0

BENDS)

2 X 90

0

BENDS

90

0

BENDS

OR “T” PIEC

Part A system installation and start-up

1. Description

2. Installation in the pipeline

2.1 General

S I Z E

φ

∆φ

S I Z E

φ

∆φ

D N

( m m )

m m

(inch)

m m

(inch)

D N

(inch)

m m

(inch)

m m

(inch)

1 0 S 8.9

(0.35)

0.4

(0.016)

3 / 8 " S 8.9

(0.35)

0.4

(0.016)

1 0 1 2 . 6

(0.50)

0.4

(0.016)

3/8" 1 2 . 6

(0.50)

0.4

(0.016)

1 5 1 4 . 9

(0.59)

0.4

(0.016)

1/2" 1 4 . 9

(0.59)

0.4

(0.016)

2 0 2 0 .9

(0.82)

0.4

(0.016)

3/4" 2 0 . 9

(0.82)

0.4

(0.016)

2 5 2 8 . 5

(1.12)

0.4

(0.016)

1 " 2 6 . 7

(1.05)

0.4

(0.016)

4 0 4 3 . 1

(1.70)

0.4

(0.016)

1/5" 4 0 . 9

(1.61)

0.4

(0.016)

5 0 5 4 . 5

(2.15)

0.6

(0.024)

2 " 5 2 . 6

(2.07)

0.6

(0.024)

8 0 8 2 . 5

(3.25)

0.6

(0.024)

3 " 7 8

(3.07)

0.6

(0.024)

1 0 0 1 0 7 . 1

(4.22)

0.6

(0.024)

4 " 1 0 2 . 4

(4.03)

0.6

(0.024)

1 5 0 1 5 9 . 3

(6.27)

0.8

(0.031)

6 " 1 5 4 . 2

(6.07)

0.8

(0.031)

2 0 0 2 0 6 . 5

(8.13)

1

(0.039)

8 " 2 0 2 . 7

(7.98)

1

(0.039)