Bm100 menu tree ams – KROHNE BM 100 HART User Manual

Page 10

Advertising
background image

BM100 Remote Operation - HC 275 / AMS

Dev.-Rev. EE, DD-Rev. 03

© 2000 KROHNE Meßtechnik D-47058 Duisburg

Page

10

Attachment B

(continued from the previous page)

Designations:

- not applicable if 'Interface Option' is disabled

(L) - Local AMS variable, that is not read/written to
instrument
* - Read-only variable

Process Variables
Status
-----------------------------------
Diagnostics and Test
Calibrate
-----------------------------------
Master reset
Reset user EEPROM
Reset factory EEPROM
-----------------------------------
Entry Code
Service Code
-----------------------------------
Audit Trail
Drawing Notes ...
Help ...
-----------------------------------
Clear Offline Configuration
Compare Configurations
Configuration Properties

Basic Setup

•

Location

----- Basic Functions -----

•

Tank Height

•

Hold Distance

•

Time Constant

•

Window Frozen

•

Level Window

•

Interface Window

------------- A01 ------------

•

Function I1

•

Scale I1 Max

•

Scale I1 Min

------------- A02 ------------

•

Function I2

•

Scale I2 Max

•

Scale I2 Min

Sensor
------------ Tank-------------

•

Tank Height

•

Hold Distance

----------- Limits -----------

•

Snsr Upper Lim

•

Snsr Lower Lim

•

Snsr Min Span

-------- Correction ---------

•

Window Frozen

•

Level Window

•

Interface Window

•

Detection Delay

•

Epsilon R

•

Settling

Process Input

•

Length Unit

•

Volume/Mass Unit

•

Time Constant

------ Display format ------
------ (AMS screens) -------

•

Level format (L)

•

Volume format (L)

Analog Outputs
------------- A01 ------------

•

Function I1

•

Range I1

•

Scale I1 Max

•

Scale I1 Min

•

AO Alarm type

------------- A02 ------------

•

Function I2

•

Range I2

•

Scale I2 Max

•

Scale I2 Min

•

AO Alarm type

HART
-- Device Identification --

•

Location

•

Device ID *

•

Date

•

Descriptor

•

Message

------ Protocol Data ------

•

Universal revision *

•

Num request preams *

•

Num response preams

•

Polling address

Service
---- Basis Parameters -----

•

Probe Length

•

Offset

•

Bottom Short-Cir.

•

Probe Position

•

Inter. Selection

------- Application ---------

•

Measurement Mode

------- Calibration ---------

•

Derivative Reference

•

Elec. Cal. Speed

•

Mech. Cal. Speed

•

Air Epsilon R

----------- Reset -------------

•

Serial Number

•

French Cmd Nmb

•

German Cmd Nmb

Device

•

Model *

•

Manufacturer *

•

Fld dev rev *

•

Software rev *

•

Write protect *

--------- User Data ---------

•

Serial Number *

•

French Cmd Nmb *

•

German Cmd Nmb *

•

Option

•

Probe Type

Strap Table, 1-20

•

Number of points

First 20 pairs
Level ! Volume/Mass

KROHNE BM100 45f9ee03

BM100 Menu Tree AMS

Strap Table, 21-40

Next 20 pairs
Level ! Volume/Mass

Strap Table, 41-50

Last 10 pairs
Level ! Volume/Mass