Installation, 13 temperatures – KROHNE OPTIFLUX 2000 EN User Manual
Page 21

INSTALLATION
3
21
OPTIFLUX 2000
www.krohne.com
4/2014 - 4000839504 - HB OPTIFLUX 2000 R04 en
3.6.13 Temperatures
CAUTION!
Protect the device from direct sunlight.
Temperature range
Process [°C]
Ambient [°C]
Process [°F]
Ambient [°F]
min.
max.
min.
max.
min.
max.
min.
max.
Hard rubber / Polyolefin
Hard rubber / Polyolefin
Hard rubber / Polyolefin
Hard rubber / Polyolefin
1
Separate flow sensor
-5
80
-40
65
23
176
-40
149
Compact with IFC 300
-5
80
-40
65
23
176
-40
149
Compact with IFC 100
-5
80
-40
65
23
176
-40
149
Compact with IFC 050
-5
80
-40
65
23
176
-40
149
Polypropylene
Polypropylene
Polypropylene
Polypropylene
2
Separate flow sensor
-5
90
-40
65
23
194
-40
149
Compact with IFC 300
-5
90
-40
65
23
194
-40
149
Compact with IFC 100
-5
90
-40
65
23
194
-40
149
Compact with IFC 050
-5
90
-40
65
23
194
-40
149
1 Polyolefin is only available for DN200...1000
2 Polypropylene is only available for DN25...150