Technical data – KROHNE OPTIFLUX 4000 EN User Manual

Page 28

Advertising
background image

6

TECHNICAL DATA

28

OPTIFLUX 4000

www.krohne.com

01/2011 - 4000818502 - HB OPTIFLUX 4000 R02 en

Chemical properties

Chemical properties

Chemical properties

Chemical properties

Physical condition

Electrically conductive liquids

Electrical conductivity

Water: ≥ 20 μS/cm

Non water: ≥ 1 μS/cm

Permissible gas content (volume) ≤ 5%

Permissible solid content

(volume)

≤ 70%

Installation condtitions

Installation

Take care that flow sensor is always fully filled.

For detailed information see chapter "Installation".

Flow direction

Forward and reverse.

Arrow on flow sensor indicates positive flow direction.

Inlet run

≥ 5 DN

Outlet run

≥ 2 DN

Dimensions and weights

For detailed information see chapter "Dimensions and weights".

Materials

Sensor housing

DN2.5...15: Stainless steel 1.4408

DN20: GTW-S 30

DN25...3000: Sheet steel, polyurethane coated

Other materials on request.

Measuring tube

Austenitic stainless steel

Flange

Standard: Carbon steel, polyurethane coated

Other materials on request.

Liner

Standard

Standard

Standard

Standard

DN2.5...15: PFA

DN20: PTFE

DN25...150: PFA

DN200...3000: ETFE

Option

Option

Option

Option

DN200...600: PTFE

DN200...1800: PU

DN200...3000: Hard rubber (Ex only)

Other materials on request.

Connection box

(only remote versions)

Standard: polyurethane coated die-cast aluminium

Option: Stainless steel

Measuring electrodes

Standard: Hastelloy

®

C

Option: Platinum, stainless steel, titanium, tantalum, low noise

Other materials on request.