Technical data – KROHNE OPTIMASS 6000 EN User Manual

Page 36

Advertising
background image

6

TECHNICAL DATA

36

OPTIMASS 6000

www.krohne.com

07/2014 - 4001894003 - MA OPTIMASS 6000 R03 en

Maximum end loadings (Stainless Steel 316 / 316L)

Maximum end loadings (Hastelloy® and Stainless Steel UNS S31803)

• DN08...50 (axial) loads have been calculated, based on 316L schedule 40 process pipework,

where un-radiographed butt welds have been used in pipe joints.

• DN80...250 (axial) loads have been calculated, based on 316L schedule 80 process pipework,

where un-radiographed butt welds have been used in pipe joints.

• The loads shown are the maximum permitted static load. If loads are cycling (between

tension and compression) these loads should be reduced. For advice, consult the
manufacturer.

-40...55

-50...40

T6

T80

-50...230

T2

T270

-50...400

T1

T440

-40...65

-50...40

T6

T80

-50...230

T2

T270

-50...400

T1

T440

S08 /

S10

S15

S25

S50

S80

S100

S150

S200

S250

Flanges

Flanges

Flanges

Flanges

20°C

40 barg

15 kN

25 kN

38 kN

48 kN

99 kN

130 kN

250 kN

300 kN

350 kN

100 barg

12 kN

17 kN

19 kN

15 kN

20 kN

100 kN

150 kN

150 kN

200 kN

230°C

32 barg

7 kN

12 kN

18 kN

25 kN

45 kN

60 kN

150 kN

200 kN

250 kN

60 barg

5 kN

20 kN

400°C

27.4

barg

5 kN

6 kN

10 kN

12 kN

20 kN

50 kN

80 kN

100 kN

150 kN

40 barg

4 kN

5 kN

20 kN

Hygienic (all connections)

Hygienic (all connections)

Hygienic (all connections)

Hygienic (all connections)

150°C

10 barg

5 kN

9 kN

12 kN

12 kN

18 kN

N/A

N/A

N/A

N/A

H08 / H10

H15

H25

H50

H80

D100

D150

D200

Flanges (not including CRN)

Flanges (not including CRN)

Flanges (not including CRN)

Flanges (not including CRN)

20°C

200 barg

12 kN

17 kN

19 kN

15 kN

20 kN

100 kN

150 kN

230°C

145 barg

5 kN

20 kN

Flanges (CRN regions)

Flanges (CRN regions)

Flanges (CRN regions)

Flanges (CRN regions)

20°C

200 barg

1

12 kN

17 kN

19 kN

15 kN

20 kN

60 kN

30 kN

10 kN

230°C

145 barg

2

5 kN

20 kN

1 D200 limited to 180 barg at 20°C
2 D100 and D150 limited to 120 barg at 230°C. D200 limited to 110 barg at 230°C

MA_OPTIMASS_6000_en_140717_4001894003_R03.book Page 36 Thursday, July 17, 2014 3:27 PM

Advertising