KROHNE DW 181-182-183-184 EN User Manual
Page 10
10
Installation and operating instructions DW 181 - 184
2 Electrical
Connections
 
Disconnect the power supply before opening the housing 
 
 
 
Number 
of 
switches 
Switch 
types 
Limit switch adjustable over entire range
 
Type 
K1 
 
A 
 
 
 
 
1 
 
Type 
K1 
B
 
Type 
K2 
C
 
Type 
K2 
D
 
Type 
K2 
E
 
 
 
 
 
 
 
 
2 
 
Type 
K2 
F
 
1 
 
Type 
KV1 
G
 
1 
 
Type 
KV2 
H
 
 
K1 
+ 
K2 
 
 
Change 
over 
(SPDT) 
• The electrical connection
conforms to the standard 
EN61010-1, protection 
class 1 (for aluminium 
housing) or class 2 (for 
PVC housing), voltage 
category III, and 
interference degree 2. 
• The DW range conforms
to EMC directives NF EN 
50 081.1 (Emission) and 
NF EN 50 082.2 
(Immunity). 
• It is obligatory to have a
switching or circuit 
breaking device, following 
present regulations. The 
devices should completely 
isolate the unit and be 
easily accessible, close to 
the unit. 
 
• Both the live (L) and 
neutral (N) wires should 
be protected by a fuse 
(4…6.3 A Time Lag). 
During the wiring 
procedure the ground wire 
should always be 
connected first (relevant 
only for aluminium 
housing). 
• EEx ia versions must be
used with a certified 
intrinsically-safe power 
supply. 
 
N.B. Use of the unit 
outside the specifications 
detailed in this manual can 
compromise the safety 
measures designed into the 
unit. Always disconnect the 
power supply before 
accessing the terminals.