2.1.3 Special conditions
2.1.4 Purging system
Devices that have the horn antenna option also have a purging system.
Figure 2-2: Risk of ESD
1 Sun cover
2 Drop antenna
3 Flange plate protection (option for the Drop antenna)
WARNING!
Aluminium housing: Possible source of ignition in a potentially explosive atmosphere. The
housing is made of either aluminium alloy or stainless steel. If the device has an aluminium
alloy housing, make sure that iron/steel objects do not hit or rub against the device.
INFORMATION!
If the device is approved for operation in zone 2, the display agrees with the low-energy impact
test requirements for this certification.
Figure 2-3: Purging system
1 ¼ NPTF purging connection