GENERAL SAFETY INFORMATION

1

5

OPTIWAVE 8300 C

www.krohne.com

02/2009 - 4000407102 - AD ATEX OPTIWAVE 8300 R02 en

1.4 Device categories

This device is suitable for use in potentially explosive atmospheres of all flammable substances
in Gas Groups IIA, IIB and IIC. It is certified for applications requiring Category 1 G (gases,
vapours or mists), 1 D (dust), 1/2 G, 1/2 D, 2 G or 2 D equipment when fitted with the appropriate
Ex ia options. It is certified for applications requiring Category 1/2 G, 1/2 D, 2 G or 2 D equipment
when fitted with the appropriate Ex d options.

1.5 ATEX nameplates

INFORMATION!
Category 1

Category 1

Category 1

Category 1
The device is installed in hazardous areas requiring Category 1 G or 1 D equipment.
Category 1/2

Category 1/2

Category 1/2

Category 1/2
The signal converter is installed in hazardous areas requiring Category 2 G or 2 D equipment.
The probe is installed in hazardous areas requiring Category 1 G or 1 D equipment.
Category 2

Category 2

Category 2

Category 2
The device is installed in hazardous areas requiring Category 2 G or 2 D equipment.
Category 2/3

Category 2/3

Category 2/3

Category 2/3
The signal converter is installed in hazardous areas requiring Category 3 G or 3 D equipment.
The probe is installed in hazardous areas requiring Category 2 G or 2 D equipment.
Category 3

Category 3

Category 3

Category 3
The device is installed in hazardous areas requiring Category 3 G or 3 D equipment.

Figure 1-1: Ex ia nameplate (device without external sensor)

1 ATEX certifcation agency code. Refer also to temperature classes

temperature classes

temperature classes

temperature classes.

2 Equipment approval categories
3 Types of device protection including approved Gas Groups (IIA, IIB or IIC) and temperature classes for hazardous areas

and maximum surface temperature (please refer to the certificate)

4 Intrinsically-safe circuit data
5 Cable entry type and size (Aluminium housing: M26 x 1.5, M20 x 1.5, ½NPT or G½; Stainless steel housing: M25 x 1.5,

M20 x 1.5, ½NPT or G½)