Technical data, 2 dimensions and weights – KROHNE OPTIBAR P 2010 C EN User Manual
Page 23

TECHNICAL DATA
6
23
OPTIBAR P 2010 C
www.krohne.com
04/2014 - 4002622502 - MA OPTIBAR P2010C R02 en
6.2 Dimensions and weights
Other standards and approvals
Other standards and approvals
Other standards and approvals
Other standards and approvals
Vibration resistance acc. to
EN 60068-2-6
G½": 20g RMS (25...2000 Hz)
All except G½": 10g RMS (25...2000 Hz)
Shock resistant (impact)
according to EN 60068-2-27
G½": 500g / 1 ms
All except G½": 100g / 1 ms
Hygiene
3-A approved; FDA approved materials
Connection plug and field housing
Figure 6-1: Dimensions for connection plug and field housing
1 ISO 4400 (cable connector is part of delivery)
2 M12x1 (4-pin)
3 Cable output
4 Cable output, cable with venting
5 Field housing
Dimensions
1
2
3
4
5
[mm]
["]
[mm]
["]
[mm]
["]
[mm]
["]
[mm]
["]
a
10.5
0.4
10.5
0.4
10.5
0.4
10.5
0.4
48
1.9
b
12
0.47
10
0.39
Ш4.3
Ш0.17
7.4
0.29
Ш49.5
Ш1.95
c
Ш34.5
Ш1.36
Ш34.5
Ш1.36
Ш35
Ш1.38
Ш35
Ш1.38
44
1.7
d
-
-
-
-
15
0.59
15
0.59
M12x1.5