KROHNE AQUAFLUX EN User Manual

Page 4

Advertising
background image

4

1 Important information for installation: PLEASE NOTE !

•

Location and position as required,
but electrode axis X – • – • – • – X
must be approximately horizontal in a
horizontal pipe run.

Y terminal box or converter housing

•

Measuring tube must be completetly filled at all times.

•

Direction of flow is arbitrary. Arrow on flowmeter can normally be ignored.
For exceptions, refer to Section ”Factory settings” in the installation and operating
instructions for the signal converter.

•

Stud bolts and nuts: to fit, make sure there is sufficient room next to the pipe flanges.

•

Vibration: support the pipeline on both sides of the compact flowmeter.
Level of vibration in conformity with IEC 068-2-34: below 2.2g for compact flowmeters
in the frequency range of 20-50 Hz with the IFC 010 K / IFC 020 K and 20-150 Hz
with the IFC 090 K.

•

Do not expose to direct sunlight,
fit a sunshade if necessary, not included with flowmeter, to be provided by customer.

•

Large meter sizes (

≥≥

DN 200 /

≥≥

8”): use adapter pipes to allow axial shifting of the

counterflanges and to facilitate installation.

X

X

•

Use only solventless detergents to clean the signal converter housing (polycarbonate).

•

Temperatures
Refer to Section 11 ”Limits” for operating pressure and vacuum load based on flange
standards and type of tube liner.

Ambient temperature

Process temperature

Compact systems

-25 to +60 °C (-13 to +140 °F)

-25 to

≤

+60 °C (-13 to

≤

+140 °F)

-25 to +40 °C (-13 to +104 °F)

-25 to

≤

+90 °C (-13 to

≤

+194 °F)

AQUAFLUX F

-25 to +60 °C (-13 to +140 °F)

-25 to > +60 °C (-13 to > +140 °F)

In storage

-20 to +60 °C (-04 to +140 °F), kept immobile,
avoid moisture and sunlight.

Transport

-

0

5 to +50 °C (-

0

4 to +140 °F),

avoid moisture and sunlight.

Y