8

Nominal size
measuring
tube and
pipe flanges

Pressure
rating or
flange class
of pipe flanges

Max.
allowable
operating
pressure

bar

psig

1)

For meter sizes DN 10 and

3

/

8

”, use pipe flanges DN 15 or

1

/

2

”.

6 Torques

Max.
torques
stud bolts

Nm

ft x lbf

. . . DIN 2501 (BS 4504)
DN 10-25 1)

PN 16/PN 40

≤

16

≤

230

0

16

11.6

DN 40

PN 16/PN 40

≤

16

≤

230

0

25

18.1

DN 50

PN 16/PN 40

≤

16

≤

230

0

45

32.5

DN 80

PN 16/PN 40

≤

16

≤

230

0

25

18.1

DN 100

PN 16/PN 40

≤

16

≤

230

0

33

23.9

DN 150

PN 16/PN 40

≤

16

≤

230

0

82

59.3

. . . ANSI B 16.5

3

/

8

”-

1

/

2

” 1)

150/300 lb

≤

16

≤

230

0

16

11.6

1”

150/300 lb

≤

16

≤

230

0

15

10.8

1

1

/

2

”

150/300 lb

≤

16

≤

230

0

25

18.1

2”

150/300 lb

≤

16

≤

230

0

45

32.5

3”

150 lb

≤

16

≤

230

0

56

40.5

300 lb

0

28

20.5

4”

150/300 lb

≤

16

≤

230

0

36

26.0

6”

150 lb

≤

16

≤

230

100

72.3

300 lb

0

66

47.7

. . . JIS
DN 10-15 1)

10 K

≤

0

7

≤

100

0

16

11.6

20 K

≤

14

≤

200

0

16

11.6

DN 25

10 K

≤

0

7

≤

100

0

16

11.6

20 K

≤

14

≤

200

0

19

13.7

DN 40

10 K

≤

0

7

≤

100

0

20

14.5

20 K

≤

14

≤

200

0

17

12.3

DN 50

10 K

≤

0

7

≤

100

0

35

25.3

20 K

≤

14

≤

200

0

24

17.4

DN 80

10 K

≤

0

7

≤

100

0

20

14.5

20 K

≤

14

≤

200

0

30

21.7

DN 100

10 K

≤

0

7

≤

100

0

26

18.8

20 K

≤

14

≤

200

0

89

28.9

DN 150

10 K

≤

0

7

≤

100

0

65

47.0

20 K

≤

14

≤

200

0

89

64.3

7. Grounding

•

Warning: All flowmeters must be properly grounded to avoid personnel shock hazard.

•

The ground conductor should not transmit any interference voltages, therefore do not ground
any other electrical devices together with this conductor.

Separate primary head IFS 1000 F with terminal box

•

A functional ground FE must always be connected.

•

Signal converters with a field power supply of > 125 mA / > 60 V for the primary heads
should not be operated with the IFS 1000 F.