5-7 Analogue Output: How to Use Model 7073 Output Cord
AC and DC output can be obtained by inserting optional Model 7073
output cord into the two-way analogue output terminal
③.
AC Output:
Can be monitored by connecting a digital multimeter to analogue output
terminal or observed as a waveform by connecting an oscilloscope.
DC Output:
Can be monitored by connecting a digital multimeter, or a recorder,
which enables many hours of monitoring. See Figure 8. With the 2413R
in the peak hold mode, DC voltage corresponding to 1/
√2 of a peak
current value can be held and output.
Refer to section 5-3, How to Use Peak Hold Function.