KYORITSU 4140 User Manual

Page 11

Advertising
background image

̶ 9 ̶

PHASEROTATION

Rated

Voltage

Remarks

50∼500V

45~65Hz

Correctphasesequence:displayed“1.2.3”and mark

Reversedphasesequence:displayed“3.2.1”and mark

Volts

Range

Display Range

Guaranteed

Voltage Range

Accuracy

500V

Volt:0 ∼ 525V

Frequency:40.0 ∼ 70.0Hz

25 ∼ 500Vrms

45 ∼ 65Hz

Volt:±(2%rdg+4dgt)

Frequency:±(0.5%rdg+2dgt)

Possiblenumberoftestswithfreshalkalinebatteries.

LOOP/PFC/PSC 

:Approx.3000timesmin(ATT)

VOLT/PHASEROTATION :Approx.100H.

5.2 Operating error

LoopImpedance(EN61557-3)

FUNCTION

Operating range compliant

withEN61557-3operatingerror

Maximum percentage

operating error

L-PE

0.40~1999Ω

±30%

L-N/L-L

0.40~19.99Ω

The influencing variations used for calculating the operating error
are denoted as follows;
Temperature

: 0 ℃ and 35 ℃

Phaseangle

:Ataphaseangle0°to18°

Systemfrequency :49.5Hzto50.5Hz
System voltage

: 230V+10%-15%

Supplyvoltage

:6.8Vto10.35V

Harmonics

:5%of3rdharmonicat0°phaseangle

 

5%of5thharmonicat180°phaseangle

 

5%of7thharmonicat0°phaseangle

D.Cquantity

:0.5%ofthenominalvoltage

Advertising