Sp 400-blue, Pin functions, Circuit diagram – Martel Electronics SP400-BLUE User Manual

Page 3

Advertising
background image

PIN FUNCTIONS

1. V+

Positive power supply to the meter.

2. GND 0V power supply to the meter (3.0 to 7.5V meter power supply applications only).
3. BL-

Connect to the meter's negative supply voltage to switch on the LED backlighting.
For meter supply voltages above 7.5V, add a series resistor Rs.
See Applications for suitable circuit diagrams.

4. INH

Positive measuring input.

5. INL

Negative measuring input.

6. DP1

Connect to V+ to display DP1 (199.9).

7. DP2

Connect to V+ to display DP2 (19.99).

8. DP3

Connect to V+ to display DP3 (1.999).

9. V-

Negative power supply to the meter (6.0 to 15.0V meter power supply applications only).

A negative supply is generated internally and mirrors the positive supply. For example: if V+ is +5V, then
the internally generated V- is -5V. When measuring with the input referenced to the same supply rail as
that of the panel meter, then the limitations on the input range are (V- + 1.5V) to (V+ - 1.5V).

LCOM

Normally Open. Connects INL to COM.

LBAT

Normally Closed. Cut this link to disable the low battery warning sign.

Note:

Solder Links:

Page 3 of 4

CIRCUIT DIAGRAM

www.lascarelectronics.com

Pins 11 and 18 not fitted as standard

RA and RB factory fitted options

SP 400-BLUE

3½ Digit Backlit LCD Voltmeter Module