Sp 400-blue, Applications, Scaling – Martel Electronics SP400-BLUE User Manual

Page 4: 5v supply operation, 9v supply operation, 3½ digit backlit lcd voltmeter module

Advertising
background image

Specifications liable to change without prior warning

SP 400-BLUE

Issue 1

February/2004

M.C.

Applies to SP 400/3

APPLICATIONS

Do not connect more than one meter to the same power supply if the meters cannot use the same signal
ground. Taking any input beyond the power supply rails will damage the meter.

5V supply operation

(3.0 to 7.5V Meter Power Supply)

9V supply operation

(6.0 to 15.0V Meter Power Supply)

SCALING

Two external resistors Ra
and Rb may be used to
alter the full scale reading
(FSR) of the meter - see
table. The meter will have
to be re-calibrated by
adjusting the calibration
potentiometer on the rear
of the module.

FSR

Ra

Rb

2V

910k

100k

20V

1M

10k

200V

1M

1k

2000V*

1M

100R

200 A

0R

1k

2mA

0R

100R

20mA

0R

10R

200mA

0R

1R

m

Voltage

Current

+

-

Ra

Rb

INH

4

5

Vin or in

I

INL

SP 400-BLUE

Page 4 of 4

*Ensure that Ra is rated for high voltage use.

+3.0 to +7.5V

+3.0 to +7.5V

-3.0 to -7.5V

+3.0 to +7.5V

V+

V+

INH

INH

INL

INL

0V

GND

V-

+

+

-

-

±200mV

±200mV

Measuring a single ended input
voltage referenced to supply, i.e. the
input voltage and the meter's power
supply share the same 0V rail.
Ensure solder link LCOM is open.

Measuring a single ended input
voltage referenced to supply, i.e. the
input voltage and the meter's power
supply share the same 0V rail.
Ensure solder link LCOM is open.

V+

INH

INL

GND

+

-

±200mV

Measuring a current from a circuit which is
floating with respect to the DPM's supply,
i.e. the current and the meter's power
supply are isolated from each other.
Ensure solder link LCOM is closed.

Measuring a current from a circuit which is
floating with respect to the DPM's supply,
i.e. the current and the meter's power
supply are isolated from each other.
Ensure solder link LCOM is closed.

Measuring an input voltage referenced to
a floating supply, i.e. the input voltage
and the meter's power supply are isolated
from each other.
Ensure solder link LCOM is closed.

Measuring an input voltage referenced to
a floating supply, i.e. the input voltage
and the meter's power supply are isolated
from each other.
Ensure solder link LCOM is closed.

www.lascarelectronics.com

1

2

4

5

1

9

4

5

+6.0 to +15.0V

V+

INH

INL

0V

V-

Rb

I

+

I-

1

9

4

5

1

2

4

5

6

8

7

DP1

No DP

DP2
DP3

3

0V

BL-

if V+<7.5V then
backlight may appear
dull or not switch on.

+6.0 to +15.0V

V+

INH

INL

V-

+

-

±200mV

1

9

4

5

3

0V

BL-

Rs=(V+ - 7.5V)

0.01

3

BL-

Rs=(V+) - (V-) - 7.5V

0.01

+3.0 to +7.5V

V+

INH

INL

0V

V-

ext

GND

Rb

Rs

I

+

I-

1

2

4

5

3

BL-

Rs=(V+) - (V- ) - 7.5V

0.01

ext

SP 400-BLUE

3½ Digit Backlit LCD Voltmeter Module