General, Installation and commissioning, Model 624 corresponding port weld-on adapter – NOSHOK 624 Series Pressure Transmitters User Manual

Page 2

Advertising
background image

General

NOSHOK series 623 and 624 pressure transmitters

are approved as non-incendive for Class I, Division 2,

Groups A, B, C and D; Dust Ignition-proof for Class II,

Division 1, Groups E, F and G; FM standards accord-

ing to FMRC 3600, 3611 and 3810.

These transmitters must be installed and operated

according to NEC and local codes. Improper installa-

tion or modifications to the electrical connection will

void the hazardous approval rating.

WIRE

COLOR

+ Supply

BROWN

+ Output

GREEN

4 mA to 20 mA 2-wire

WIRE

COLOR

+ Supply

BROWN

Common

GREEN

+ Output

WHITE

1 Vdc to 5 Vdc

.5 Vdc to 4.5 Vdc

3-wire

1.61" (41mm)

ø1.18" ±..003

(30mm)

ø.71" ±..003

(18mm)

O-ring 1.17" x 1.41" x .08"
(29.7mm x 35.7mm
x 2.0mm)

O-ring 1.02" x .08"
(26mm x 2mm)

1.06" (27mm)

O-ring .73" x .94" x .08"
(18.5mm x 23.9mm

x 1.5mm)

O-ring .59" x .08"
(15mm x 2mm

G 1 B

G 1/2 B

.8

1

"

(2

0

.5

m

m

)

.39"

(10mm)

.8

1

"

(2

0

.5

m

m

)

.39"

(10mm)

1

O,1 A

ø1.97" (50mm)

ø1.97" (50mm)

ø1.32" ±.007

(33.5mm)

ø.84" ±.007

(21.3mm)

ø

G 1

G 1/2

.

1.20" ±.003

(30.5mm)

.76" ±.003

(19.4mm)

ø1.19" ±.003

(30.1mm)

ø.72" ±.007

(18.2mm)

A

A

.5

9

"

±

.0

0

7

(1

5

m

m

)

.5

9

"

±

.0

0

7

(1

5

m

m

)

.8

1

"

±

.0

1

2

(2

0

.5

m

m

)

.8

1

"

±

.0

1

2

(2

0

.5

m

m

)

.4

1

"

(1

0

.5

m

m

)

T

O,1 A

.4

1

"

(1

0

.5

m

m

)

T

x

x

x

x

NOTES: U.S. INSTALLATIONS
1. INSTALL PER NATIONAL ELECTRICAL CODE AND LOCAL CODES, AS APPLICABLE
2. TO MAINTAIN TYPE 4X SEALING OF SERIES 623, 624 TRANSDUCER, USE THREAD
SEALANT WHEN INSTALLING CONDUIT

THIS EQUIPMENT IS SUITABLE FOR LOCATIONS:
CLASS I, DIVISION 2, GROUPS A, B, C, D
CLASS II, DIVISION 1, GROUPS E, F, G

SERIES 623, 624 APPROVED/CERTIFIED

NON-INCENDIVE TRANSDUCER

4 mA to 20 mA

1-5V, 0.5-4.5V

CONTROL EQUIPMENT

Model 624 front flush connections

+ Supply

+ Supply

+ Output

Common

+ Output

1

2

3

4

BROWN

GREEN

WHITE

BARE

HAZARDOUS LOCATION

NON-HAZARDOUS LOCATION

Model 624 corresponding port weld-on adapter

G 1/2 B

G 1 B

For ranges 0 to 30 psi and higher

For ranges less than 0 to 30 psi

For ranges 0 to 30 psi and higher

For ranges less than 0 to 30 psi

Installation and commissioning

NOSHOK series 623 and 624

transmitters are supplied with a

1/2

NPT male conduit electrical

connection with a 6 ft

jacketed cable. Series 623 and

624 transmitters meet the

requirements of a single

seal device as defined by

ANSI/ISA 12.27.01-2003.

Series 623 has a thread-

ed process connection and

4.50

(114

.3mm)

1/2 NPT

male

conduit

1.06

(2

6.9

mm)

.51

(12.95mm)

Advertising
This manual is related to the following products: