Noshok transmitters transducers, Wiring diagrams & electrical connections for, Installation – NOSHOK 100 Series Transmitters Transducers Wiring Diagrams & Electrical Connections User Manual

Page 5: Maintenance/calibration

Advertising
background image

CORPORATE HEADQUARTERS

1010 West Bagley Rd. • Berea, OH 44017

440.243.0888 • FAX 440.243.3472

E-mail: [email protected]

Web: www.noshok.com

Wiring Diagrams & Electrical

Connections for:

100, 200, 300, 612, 613, 615/616,

640, 660, and 800 Series

NOSHOK

TRANSMITTERS

TRANSDUCERS

Installation:

NOSHOK pressure transmitters/transducers may

be mounted in any plane with negligible effect on

performance. Although these units are designed

and manufactured to withstand substantial shock

and vibration, it is recommended that they be

mounted in an area of minimal vibration. Always

use a wrench on the wrench flats when installing.

NEVER use a pipe wrench on the housing or in the

area of the electrical connection.

Maintenance/Calibration:

NOSHOK pressure transmitters/transducers

require no maintenance. Recalibration is

dependent on the users Quality Assurance

Program. If no program is in place, NOSHOK

recommends a 1 year cycle.

Alignment Procedure (applies only to 100,
200, 615/616, and 640 series):

Using a pressure source and meter with adequate

accuracy, perform the following steps:
• Open sensor

• With no pressure applied,

adjust the “Z”

potentiometer for the

correct Zero output

• Apply the correct full scale

pressure to the unit

• Adjust the “S”

potentiometer for the

correct Span output

NWD 08-3

Span

Zero

SERIES 660

SERIES 800

4 mA to 20 mA, 2 wire

Power

Supply

+ Supply

Output

+ Output

Load Limitations

4 mA to 20 mA Output Only

Vmin = 10V + (.020 x R

L

)

R

L

= R

S

+ R

W

R

L

= Loop Resistance (ohms)

R

S

= Sense Resistance (ohms)

R

W

= Wire Resistance (ohms)

Series 800

4 mA to 20 mA

CONNECTION TYPE (CODE)

+ SUPPLY

+ OUTPUT

Hirschmann (8 or 14)

1

2

Hirschmann w/ Cable (1)

Red

Black

M12 x 1, 4-Pin (25)

1

3

Series 800

0-10 Vdc

CONNECTION TYPE (CODE)

+ SUPPLY

COMMON

+ OUTPUT

Hirschmann (8 or 14)

1

2

3

Hirschmann w/ Cable (1)

Red

Black

White

M12 x 1, 4-Pin (25)

1

3

4

Example: Red / 1 = Applicable color wire / din plug number.

Load Limitations

4 mA to 20 mA Output Only

Vmin = 10V + (.020 x R

L

)

R

L

= R

S

+ R

W

R

L

= Loop Resistance (ohms)

R

S

= Sense Resistance (ohms)

R

W

= Wire Resistance (ohms)

Series 660

4 mA to 20 mA

CONNECTION TYPE (CODE)

+ SUPPLY

+ OUTPUT

Mini-Hirschmann (7)

1

2

Mini-Hirschmann w/ Cable (1)

Red

Black

M12 x 1, 4-Pin (25)

1

3

Integral Cable (36)

Brown

Green

Wiring - M12 x 1 4-pin

round connector

Wiring - Mini-Hirschmann

connector

Series 660

1-5 Vdc, 0.1-10 Vdc

CONNECTION TYPE (CODE)

+ SUPPLY

COMMON

+ OUTPUT

Mini-Hirschmann (7)

1

2

3

Mini-Hirschmann w/ Cable (1)

Red

Black

White

M12 x 1, 4-Pin (25)

1

3

4

Integral Cable (36)

Brown

Green

White

Current output, 2 wire

Power

Supply

+ Supply

Output

+ Output

1

3

2

Power

Supply

+ Supply

Output

+ Output

Common

1

3

2

Voltage output, 3 wire

Current output, 2 wire

Power

Supply

+ Supply

Output

+ Output

Voltage output, 3 wire

Power

Supply

+ Supply

Output

+ Output

Common

0 Vdc to 10 Vdc, 3 wire

Power

Supply

+ Supply

Output

+ Output

Common

Advertising