Dimensions

80 amp

480 Volt

Model 925-480-80

60 amp

480 Volt

Model 925-480-60

30 amp

480 Volt

Model 925-480-30

60 amp

240 Volt

Model 925-240-60

30 amp

224 Volt

Model 925-240-30

Three Phase

60 amp

240 Volt

Model 900-240-60

40 amp

240 Volt

Model 900-240-40

20 amp

240 Volt

Model 900-240-20

Single Phase

Circuit Breaker

Voltage

Control Panel

Control Options

All panels have an operator interface that allowed the heater to be controlled in any one of three operator selected modes.
Manual Operation
The digital control is used to directly set the percent output of the lamps from 0 to 100%.
Automatic-Temperature Control
The controller takes the input from a type “K” thermocouple or IR sensor and regulates the lamp output so the product temperature will
match the preset value.
Automatic-Line Speed
The controller will take the output from a 0 to 10 VDC line that references line speed and vary the lamp output from 0 to 100%
proportionally.

Once you have determined the appropriate size Model 4555 PanelIR Heater, please refer to the Power Controller to select the correct
controller for your application.