Warning, Figure 3-2 – Precision Control Systems DryIR 6030 User Manual

Page 11

Advertising
background image

Model 6030 Dry IR Drying System Instruction Manual


Note: The Model 6030 will not operate unless a transport signal is supplied to the interlock

circuit.


Typically, an interlock cable is supplied from the transport and is connected on top of the blower
housing, near the ON/OFF switch.

WARNING!

Disconnect the power to the heater module before proceeding.


To connect the interlock to the transport:

1. Remove the gray connector from the top of the unit.
2. The white insert can be removed from the housing by loosening the 4 screws that

secure it into the housing.

3. Route the wiring through the wiring gland in the housing.
4. The interlock wiring is connected to pins 1 and 4. To prevent the heater module

from running when the transport is stopped, the transport interlock power source
needs to be off when the transport is stopped.

5. Reassemble the connector and tighten the wiring gland.

Note: After completely installing the Model 6030, please ensure the stability of

the overall assembly.

Figure 3-2

7

Advertising