INSTALLATION – INDOOR DOME

1. Using the drilling guide, drill the mounting

holes and cable hole in place on the ceiling or
wall.

2. To remove dome cover, turn the dome body

counterclockwise until locators reach end of
travel and pull off. Push the liner on the sides
where the patterns are put in the teeth of a
comb and pull it out.

3. Attach the housing to the ceiling using suitable fasteners, M6x35 tapping screws are

supplied. Only use if they are suitable. Turn the housing in the right direction about
16 degrees to lock in place.


4. The assembly of the dome body and liner is in reverse order of disassembly. Finally,

lock dome body with locking screw (M3X5) from the accessory kit.