SPECIFICATIONS*

GENERAL INFORMATION

Page 1

TABLES AND DIAGRAMS

EX800-Series insertion electromagnetic flowmeters are
designed for use with conductive liquids in 1 to 12” pipe. A
choice of materials (stainless steel, brass, and PVC) allows
the meter to adapt to a range of temperature, pressure, and
corrosive environments.
The EX800 is highly suitable for difficult applications with
changing viscosities and pulsating flows, such as air-driven
diaphragm pumps. With no moving parts, these meters can
be used in “dirty” applications where debris would foul a
mechanical meter. Like all magmeters, when used in chemical
injection applications, these meters should be installed
upstream of the chemical line (or far enough downstream to
allow complete mixing of fluids before the meter).
Designed for modularity and versatility, the EX800-Series has
a current-sinking pulse output that can be combined with the
appropriate transmitter or indicator for the application. For

analog output and display of rate and total, an FT420 can be
used. Blind analog output is provided by the AO55. The PD10
can be used to divide the pulse for pacing chemical metering
pumps and the DL76 (data logger) is also compatible. Modules
can be wall- or meter- mounted. If the EX800 meter is used with
a programmable controller, the output signal can be fed direct,
with no other conditioning required.
EX800-Series fixed depth insertion meters require special
fittings. Factory installation in the fitting ensures correct depth
placement in the pipe. The EX800-Series meter can be ordered
in a full power model when a source of electricity is available, or
in a low power model that can run on an external battery with
solar panel.

Reverse flow output and immersibility are optional.

FEATURES

PVDF electrode cap

O-ring, EPDM (Viton optional)

Cover, or transmitter or indicator module
Powder coated aluminum housing

Sensor body (Stainless, Brass, PVC)

Hastelloy electrodes

Cable strain relief

1” to 12”

316 SS/Brass/PVC

Hastelloy

Cast powder-coated aluminum

PVDF (Kynar)

EPDM standard (Viton optional)

12 - 25 Vdc, 250 mA

12 - 25 Vdc, 40 mA average with 250 mA peaks

0.28 - 20 ft/sec (0.08 - 6.09 m/sec)

0˚ to 160˚ F (-17˚ to 72˚ C)

32˚ to 200˚ F (0˚ to 93˚ C)

32˚ to 130˚ F (0˚ to 55˚ C) @ 0 psi

200 psi (13.8 bar)

150 psi (10 bar) @ 75˚ F

20 microSiemens/cm

+/- 1% of full scale

Square wave pulse, opto isolated, 550 Hz @ 20 ft/sec

Software, defaults to zero flow

Pipe Size

Materials Mechanical

Electrodes

Housing

Electrode Cap

O-Ring

Power

Full Power

Low Power

Flow Rate

Temperature Ambient Temp

Fluid Temp : Brass/SS

Fluid Temp: PVC

Pressure Brass/SS

PVC

Minimum Conductivity

Calibration Accuracy

Output

Empty Pipe Detection

*Specifications subject to change • Please consult our website for current data (www.seametrics.com).

Advertising