Specifications – Seametrics PE102 User Manual

Page 2

Advertising
background image

The PE102 magmeter is designed for low-flow chemical injec-

tion or difficult-to-meter applications with pulsating metering

pumps in 3/4” to 1/4” pipe/tube. The housing is made of stur-

dy splashproof HDPE plastic.

With no moving parts, the PE102 can handle fluids contain-

ing particulate matter without clogging or jamming, keeping

maintenance at a minimum. With no metallic parts (100%

PVDF body and PVDF carbon fiber-filled electrodes), the me-

ter is corrosion-resistant and compatible with a wide range of

chemicals. Accuracy is maintained with conductive fluids (>20

microSiemens) of varying viscosities and densities.

The PE meter is compact enough to fit most pump/injection

systems. With zero straight pipe required after an elbow, it

can be easily mounted in tight spaces. The mounting bracket

adds stability.

The PE meter has an optocoupled current sinking pulse out-

put that can be connected to the Seametrics FT420 rate/total

display or FT520 batch processor, as well as a 4-20 mA loop

for powering analog devices. Outputs and power are provided

through a cable with 8-pin female circular connector.

GENERAL INFORMATION, FEATURES and SPECIFICATIONS

FEATURES

Sturdy HDPE housing

8-pin circular bulkhead connector, 20 foot (6 meter) cable provided

FlareTek fittings

are standard

Threaded NPT adapters

can be purchased separately

(available in polypropylene or

PVDF, PVDF shown)

Internals made of chemical and corrosion-resistant PVDF

Mounting bracket

3/4”, 1/2”, 3/8”, 1/4”**

FlareTek fittings standard in 3/4” or 3/8” flowbody; NPT threaded adapters also available

PVDF
PVDF carbon fiber-filled
PVDF carbon fiber-filled
HDPE with glass fiber
PVDF
Polypropylene or PVDF
EPDM or Viton

0˚ to 130˚ F (-18˚ to 54˚ C)
32˚ to 200˚ F (0˚ to 93˚ C)
150 psi

20 GPM Max. (0.2 GPM cut off)
3 GPM Max. (0.03 GPM cut off)
+/- 1% plus +/- 0.005 GPM of reading across rated range
+/- 1% plus +/- 0.002 GPM of reading across rated range
Optocoupled current sinking or current sourcing pulse output: 30 Vdc, 5 mA max

4-20 mA current loop: 7 Vdc plus load voltage drop min; 50 Vdc max

PE102-075: 500 pulses/liter (1892 pulses/gallon)
PE102-038: 1,000 pulses/liter (3785 pulses/gallon)
10-15 Vdc, 150 mA (linear power supply recommended)

>20 microSiemens

Hardware/software, conductivity-based

NEMA 4X standard; IP 66 Splashproof standard

Pipe Size

Fittings

Materials Body
Electrodes
Ground
Housing

Fittings (FlareTek)

Adapters (NPT)

O-Rings (for NPT)

Temperature Ambient

Fluid

Pressure

Flow Range

-075

-038

Accuracy

-075

-038

Output Signal

-075

-038

Power

Conductivity

Empty Pipe Detection

Environmental

SPECIFICATIONS*

*Specifications subject to change • Please consult our website for current data (www.seametrics.com).

**Requires adaptors

Advertising