AO55W Pulse-to-Analog Converter

WMX101 Cable

Power Supply

8-32 Vdc

at 30 mA max

(see

WARNING)

WMX101

Blue
Orange

Black
Red

Shielded

Direct Burial Cable

22 AWG Stranded

White (-)

Green (+)

(-)

(

+)

Drain Wire

Do

Not

Use

{

0 9

8

76

5

43

2 1

0 9

8

76

5

4

3

2 1

0 9

8

76

5

43

2 1

0 9

8

76

5

4

3

2 1

Power

Sensor

4-20 mA

Frequency

S

Not

Used

+

S

-

DL75W or DL76W Data Logger

Battery

Not

Used

WMX101 Cable

Power Supply

8-32 Vdc

at 30 mA max

(see

WARNING)

WMX101

Blue
Orange

Black
Red

Shielded

Direct Burial Cable

22 AWG Stranded

White (-)
Green (+)

(-)

(

+)

Drain Wire

Do

Not

Use

{

FT420W Remote Rate/Total Display

Po

we

r

4-20 mA

Sensor Input

PULSE

PASSTHRU

PULSE

SCALED

WMX101 Cable

Power Supply

8-32 Vdc

at 30 mA max

(see

WARNING)

Not

Used

WMX101

Blue
Orange

Black
Red

Shielded

Direct Burial Cable

22 AWG Stranded

White (-)
Green (+)

(-)

(

+)

Drain Wire

Do

Not

Use

{

External Power Input Required - 12-32 Vdc

DL75 or DL76/WMX101

Page 8

CONNECTIONS DIAGRAMS (WMX101)

The WMX101 requires a power source of 8 to 32 Vdc at 30

mA max (see WARNING). The WMX101 power cable also

serves as a pulse output if needed for remote reading, data

logging, signal conversion, or telemetry.

FT420/WMX101

Orange and Blue

: Serial Output (Do Not Use)

Green (+) and White (-)

: Pulse Output, 30 Vdc max, 10 mA max

Red (+) and Black (-)

: External Power, 8-32 Vdc at 30 mA max

Drain

: Connect to earth ground (see WARNING)

AO55/WMX101

WMX101 Cable Color Codes

WARNING:

Using an unregulated power

supply >18 Vdc may damage the meter

due to AC line input voltage fluctuation.

WARNING:

Using an unregulated power

supply >18 Vdc may damage the meter

due to AC line input voltage fluctuation.

WARNING:

Using an unregulated power

supply >18 Vdc may damage the meter

due to AC line input voltage fluctuation.