SPECIFICATIONS

Page 3

FLOW RANGE (3” - 12”)

Meter

Size

3”

4”

6”

8”

10”

12”

Gal/Min Liter/Sec Gal/Min Liter/Sec

Gal/Min Liter/Sec Gal/Min Liter/Sec Gal/Min Liter/Sec Gal/Min Liter/Sec

Minimum

7.5

.47

12

.75

32

2

60

3.8

95

6

130

8.2

Maximum

700

44.2

1,000

63

2,400

151.4

4,400

277.6

7,000

441.6

10,000

630.9

3”,4”, 6”, 8”, 10”, 12”

ANSI 150 lb. drilling

150 psi (10.3 bar) working pressure

10˚ to 130˚ F (-12˚ to 54˚ C)
-40˚ to 158˚ F (-40˚ to 70˚ C)
+/- 1% of reading for flow between 10% to 100% of max flow

+/- 2% of reading for flow from cutoff to 10% of max flow
Ductile cast iron, powder coated w/NSF61 listed epoxy powder

Welded steel, epoxy-coated

Noryl®
Santoprene/Polypropylene
Diecast aluminum, powder-coated (non-IP68)

Ductile Cast Iron (IP68)

316 stainless steel

EPDM
Rate Total
5

8

Gallon/Minute, Liter/Minute, Liter/Second,

Gallon, Gallon x 1000, Liter, Liter x 1000, Mega Liter,

Cubic Feet/Minute, Cubic Meter/Hour,

Cubic Meters, Cubic Meter x 1000, Cubic Feet,

Million Gallon/Day, Mega Liter/Day

Cubic Feet x 1000

WMX101:

8-32 Vdc at 30 mA max, with auxiliary battery for continuous operation during power failures

NOTE: Using an unregulated power supply >18 Vdc may damage the meter due to AC line input voltage fluctuation
WMX104:

2 Lithium 3.6V “D” batteries, replaceable, 1 year life under continuous use.

WMX101:

Current sinking pulse, opto-isolated, 30 Vdc at 10 mA max

WMX104:

Pulse output available only with addition of post-factory output cable

High Frequency; 10 units/pulse; 100 units/pulse; 1000 units/pulse

3”

4”

6”

8”

10” 12”

25.228

16.362

6.307

3.344 2.150 1.530

>20 microSiemens/cm
Hardware/software, conductivity-based
NEMA 4X Standard (IP68 Option)

Pipe Sizes

Fittings

Pressure

Temperature Operating

Non-Operating

Accuracy

Materials

Body (3” Only)

Body (4”-12”)

Liner (3” Only)

Liner (4”-12”)

Electronics Housing

Electrodes

O-ring (3” Only)

Display

Digits

Units

Power

Pulse Output

Signal

Pulse Rates

High Frequency

(pulse/gal)

Conductivity
Empty Pipe Detection
Environmental

SPECIFICATIONS*