GENERAL INFORMATION & SPECIFICATIONS

Page 2

Designed for use as a meter accessory, the PD10 divider is

used primarily for pacing electronic metering pumps. Any

number from one to 9999 can be set on rotary switches.

Each time the divider has received the set number of pulses

from the meter, it puts out one pulse to stroke the pump.

The PD10 is also useful in boiler and cooling tower feed and

bleed operations, and for lowering frequency output of high

frequency meters. Compatible with all Seametrics flow meters,

the PD10 creates a programmable pulse meter with an easily

adjustable pulse rate.

The PD10 comes in two different housings: an enclosure that

can be mounted near the pump, and a watertight housing for

mounting on the meter.

FEATURES

SPECIFICATIONS*

Wall (Pump) housing shown

(Meter mount also available)

Protective cover

Mounting Holes:

(Double-backed pressure-sensitive

tape also supplied standard)

Rotary Switches (4)

Potted for environmental

protection

Input connector for

Seametrics meter connector

To leads or metering

pump connector

Epoxy-encapsulated ABS housing with cover

Cast aluminum sealed housing

0˚ to 130˚ F (-18˚ to 55˚ C)

1 to 9999

Rotary switches

7 - 30 Vdc @ 4 mA

20 mA

350 Hz (pulses/second)

8 Hz (pulses/second)

Solid state relay; 0-250 V, 170 mA max AC/DC

0.1 second

Seametrics connector

Terminal

Pump connector on 24 inch lead

Comes with 18 foot lead

Enclosure

Wall (Pump) Mount

Meter Mount

Temperature

Divider Range

Setting Mechanism

Power

Maximum Sensor Load

Maximum Input Frequency

Maximum Output Frequency

Output

Output Pulse Width

Input Connection

Wall Mount

Meter Mount

Output Connection

Wall Mount

Meter Mount

*Specifications subject to change • Please consult our website for current data (www.seametrics.com).