Pd10, Pd10w/non-lmi pump pd10w/non-lmi pump – Seametrics PD10 User Manual

Page 3

Advertising
background image

PD10 PULSE

DIVIDER

To adjust divider , disconnect from power

then remove cover and set switches

If a metering pump is used that requires a connection other

than the LMI connector supplied, cut the LMI connector off.

Connect the PD10W to the pump using the diagram below in

conjunction with the wiring diagram in the pump manual.

The input connector on the control mates with any three-pin

Seametrics connector. (Meters or flow sensors to be used with

a PD10W should be ordered with Seametrics connectors.)

1

2

3

Page 3

INSTALLATION & CONNECTIONS

The PD10M is factory-mounted on the flow sensor. The PD10W

is mounted by attaching it to the metering pump with the in-

cluded double-backed, pressure-sensitive tape. Alternatively,

the control can be wall mounted with screws using the mount-

ing brackets that extend out either side.

PD10 Meter Mount

SENSOR

POWER

S

+

-

+

-

0 1 2

3

45

67

8

9

0 1 2

3

45

67

8

9

0 1 2

3

45

67

8

9

0 1 2

3

45

67

8

9

OUTPUT

+

-

PD10M

www.seametrics.com

Flow Sensor

Red

White

Black

Electronic

Metering

Pump

7 - 30 Vdc

Power Supply

+

-

LMI Pump

MOUNTING

CONNECTIONS
The PD10 meter mount can be connected as shown.

PD10W/LMI PUMP

The 24" pigtail that extends from the PD10W connects to an

LMI metering pump and is connected as shown.

The input connector on the control mates with any three-pin

Seametrics connector. (Meters or flow sensors to be used with

a PD10W should be ordered with Seametrics connectors.)

PD10W/LMI Pump

Sockets

1. Ground

2. Input Signal

3. Sensor Power

+7-30 Vdc*

Sockets

1
2

4
3

LMI Connector

(supplied with

PD10W)

Seametrics

Sensor

Connector

(order with

flow meter)

1. Auxiliary Power Source

2. Pulse Input

3. Ground

4. No Connection

PD10W/NON-LMI PUMP

PD10W/Non-LMI Pump

PD10

Red

Black

Green

White

7-30 Vdc
Ground

Signal +

Common

PD10W

Meter

PD10M meter mounted version

Power for the PD10 can be supplied by the metering pump if

the pump has a sensor power supply. This is the case with

LMI externally-paced metering pumps. Some pumps require

an external power supply, available from Seametrics. LMI

and Seametrics connectors are available.

CAUTION:

Power supplies 18 Vdc and higher must be regulated to

prevent damage to the PD10 from voltages exceeding it's

30 V allowable maximum supply voltage caused by AC line

variations and light loading.

POWER SOURCE

POWER

OUTPUT

+

+

*CAUTION:

If power is supplied to the flow sensor from the

PD10, ensure that the voltage supplied to the sensor does not

exceed the sensor's allowable maximum input voltage.

2
3

1
4

5

-06 Option

-106 Option

Sockets

1. Remote On

2. Ground

3. Pulse Input

4. Aux. Power Source

5. Not Used

Black

Red

Advertising