Ar ch ive d – Seametrics AG2000 v.1 User Manual

Page 3

Advertising
background image

Pair 1-Black

Pair 1-Red

Pair 3-Black

Pair 3-Red

DC30/DC35
Shielded Burial Cable,
3 Twisted Pairs,
22 AWG Stranded

Pair 2-Black

Pair 2-Red

Serial Output

Technician

Use Only

Pulse (-)

Pulse (+)

External Power
12-18Vdc

Vcc (-)

V (+)

Scaled Pulse
Output

Blue

Orange

White

Colored Sleeves*

*Colored Sleeves readily identify the 3 pairs.

If the cable needs to be cut back, the pair

identification is printed on each wire.

Drain Wire

(Connect to

Earth Ground)

Page 3

POWER SUPPLY and OUTPUTS

Battery Power (standard). The AG2000 is powered by

a non-rechargeable battery pack with an average lifespan

of 3 years. Lifespan varies somewhat based on usage

(less current is required during periods of empty pipe;

somewhat more when the pipe is full but there is no flow;

and the highest current draw occurs when the pipe is full

and flowing).

The display reads “Low Batt” when there is approximately

3 days of use left in the battery (see illustration at right).

Replacement instructions come with the custom battery

pack available from your dealer or SeaMetrics (Part

#31126).

External Power (optional). Where 7-24 Vdc power is

available, the life of the battery pack can be indefinitely

extended by the addition of an external power input cable.

When external power is used, the batteries serve as backup

in case of power failure. The display reads “P” to indicate

that external power is in use (see illustration at right).

When the display is reading numbers/letters but neither

the “Low Batt” or “P” symbol is displayed, the meter is

functioning normally under battery power (see illustration

at right). When the display is completely blank, the meter

is not powered (see illustration at right).

Solar Power (optional). In most areas of the US, a 12-

volt, 5 watt solar power unit (panel, charge controller and

battery) should suffice to operate the meter. In this case,

the internal batteries will serve as backup and battery life

will be conserved.

Optional Input and Outputs. An optional cable, factory-

installed or field-installed by an authorized individual,

provides power input, pulse output (for telemetry and data

logging functions), and serial output (for technician use in

custom telemetry applications). See diagram below.

Low

Batt

Low Battery Indicator

External Power Indicator

Battery Power

Display Reading. There are two lines to the display, the

bottom line for flow rate and the top line for accumulated

total. Measurement units are pre-ordered and factory-set

and can be changed in the field only by an authorized

individual.

Optional Input/Output Cable

No Power

AR

CH

IVE

D

(Includes Dates 7/19/06 to 1

1/06)

Advertising