Ar ch ive d – Seametrics AG2000 v.1 User Manual

Page 4

Advertising
background image

LT-13318-C

7/19/06

SeaMetrics Incorporated • 19026 72nd Avenue South • Kent, Washington 98032 • USA

(P) 253.872.0284 • (F) 253.872.0285 • 1.800.975.8153 • www.seametrics.com

Problem

Probable Cause

Try...

Blank display

Flow rate steadily reads

zero when there is flow

Flow rate intermittently

drops when there is flow

Jumpy reading

Replace battery pack (part #31126)

Reading will resume when flow increases

Reposition meter for full pipe

Note flow direction arrow, reverse meter

Reposition meter for full pipe or rotate to

avoid bubbles (see page 2)

Check for proper ground

Use external power source

(allows more flow averaging)

Dead battery

Flow is below cutoff (very low)

There is air in the meter

Meter is installed backward

There is air in the meter

Missing or incorrect ground wire

Pulsing flow

FLOW RANGE

TROUBLESHOOTING

4”

6”

8”

10”

Gal/Min Liter/Sec

Gal/Min Liter/Sec

Gal/Min Liter/Sec

Gal/Min Liter/Sec

12

45

32

120

60

230

95

360

500

1,890

1,200

4,550

2,200

8,330

3,500

13,250

Flow Range

Minimum

Maximum

AR

CH

IVE

D

(Includes Dates 7/19/06 to 1

1/06)

Advertising