EM100/102 TROUBLESHOOTING GUIDE

Problem Possible Causes Possible Solutions

Analog output at 0 mA

Analog output is 4 mA
with flow

No pulse output

Flow rate incorrect

No loop power

Unit not grounded

Flow reversed

Reversed output connections

Not grounded

Reversed flow

Missing or incorrect ground wire

Fluid conductivity <20 uS/cm

Empty pipe

4-20 mA loop needs an external
power supply - if missing, add it

Connect to earth ground

Note flow direction arrow, reverse
direction to match

Change output connection

Connect to earth ground

Change flow direction

Check for proper grounding

Select other flow meter

Install meter in vertical position

OPERATION

When the newly-installed meter is first powered up, particularly if it has been dry prior to start up, it can take from

a few seconds to a minute for the signal to stabilize. In normal operation, keeping the meter filled with fluid is

recommended to prevent this delay. An empty pipe detection feature will normally respond to lack of liquid in the

pipe, and will register zero flow, but under certain rare conditions it is possible for this feature to fail to recognize

the empty pipe. See the warning under “Mounting” regarding this possible problem.

The optional 4-20 mA signal outputs 4 mA at zero flow and 20 mA at maximum rated flow. The standard pulse

signal is a 50% duty cycle pulse set at 1000 pulses/liter (3785 pulses/gallon).