Connections

the chart in the flow sensor instructions, based on pipe
size. Set the number with

keys. The digit which

is underlined is the one being set. The

moves one

digit to the left. The

increases the digit. When the

appropriate number has been set, press

again to

move on to the next menu item.

Set Pulse Out. An output pulse is activated at the
selected volume intervals if this feature is in use.
Otherwise, it does not need to be set.

Set 20 mA Out. A 4-20 mA analog output is standard
on this unit. If a 4-20 mA current loop is connected, set
the flow rate, in the desired units, at which the peak 20
mA is desired. The controller will automatically scale the
4 mA output to zero flow.

Clear Total. This function resets the running total back
to zero. It is unrelated to the regeneration function, and
can be ignored unless it is needed. To reset to zero, press

and

simultaneously, as instructed.

Operation

Set Batch Size. Set the batch size for the desired
number of units, using

and

keys. If the staged

shut-off feature is not being used, this is the only setting
required for the batch.

Set Prewarn. This is only used for a staged shut-off.
The number set is the number of units early (before the
end of the batch) that Relay 2 will shut off.

Start Batch. Pressing the Start/Stop key starts the batch
by energizing Relay 1. The indicator for Relay 1 will light,
indicating normal operation. The indicator for Relay 2
may also light, depending on the prewarn setting. If
staged shut-off is being used, the Relay 2 indicator light
should go out before the end of the batch, at the prewarn
set point.

The batch will continue on to the set amount unless it is
halted in the middle by pressing the Start/Stop key again.

Pulse 1

Alternate

low-voltage power

12-24 VDC

Pulse 2

Relay 2

Relay 1

NC
COM

NO
NC

NO

COM

Batch Outputs

Line

Neutral

Ground

Resume

0-10 V

Sensor input

Analog
Outputs

4-20 mA

External Power

Internal Power

Start/Stop

+

– +

s1

+

s2

RESUME

COM

BATCH

Remote
Controls

Pulse Outputs

(for metering pumps)

Main

power fuse

250 mA

DC Power fuse
1 Amp

Power

loop power

jumper

Ribbon connector

from display board

Meter

Ground

Power signal

RED

WHITE

BLACK

Dry contact

+

Relay Pulse

10 Amp