Staged Shut-off Application

4 of 4

TX Flow Sensor

High-Flow

Valve

Low-Flow

Valve

Tank

FT520

Caution: Always disconnect
power to the unit before opening

the terminal cover. Do not recon-

nect power until all connections
have been made and the terminal

cover has been replaced.

!

Stop Batch/Resume Batch. Pressing the Start/Stop
key anywhere in the batch will stop it. It will remain
stopped until the Resume key is pressed. Pressing the
Start/Stop key again allows the batch to restart from
zero.

Choice of Displays for Batching. When in Operation
Mode, press

to change the type of display. Running

Totalizer (“T”) accumulates a Total Flow until it is reset.
Batch (“B”) accumulates the flow of the present batch
only, then resets. Bar Graph (“

”) graphically indicates

from left to right, how much of the batch has already
accumulated.

Repair

The only field-repairable component on the FT520 is the
fuse. If failure is due to a cause other than a blown fuse,
it is necessary to replace the entire board stack. Contact
your distributor for information.

High-Flow Valve

Low-Flow Valve

Relay 1

Relay 2

NC

COM

NO

NC

NO

COM

Power
Source

Conection for Staged Shut-off

5.50"

gasket

PANEL
CUTOUT

5.50"

6.03"

6.03"

1/4" holes (4 required)

Panel Cut-out