SHIMPO DT-601CG User Manual

Page 25

Advertising
background image

Mode#

A input : Setting of EXP value and frequency divider

0 2

A

B

C

D

E

F

0

1.

1

0

0

0

frequency divider : 3digits 1/1 - 1/999
(000 to be 1/1000)

EXP value (10

-n

)

n = 0 - 9

[ EXP value]

Setting of the ten's power (minus).
Combine with [Mode 01] and set the scaling data (converter).

[Frequency divider]

Set the input pulse. If the pulse per rotation is known, input that value.
The calculation will be more accurate.

<caution>

When using frequency divider, display turn to be ZERO or display offset value when reset.
However,the accumulated frequency divider value will not be erased.

[example]

When the frequency divider is set to 003(1/3), outcome will be as follows;
3 pulse output per 1 rotation, and 0.5m roller sending per 1 rotation.

Using only scaling data (converter) might cause some error. In that case, divide the input.

Setting should be as follows

Mode 01

0

1.

5

0

0

0

0.5 = 5000x10

-4

Mode 02

0

2.

4

0

0

3

Frequency divider should be 3 as 1rotation
produces 3pulse output.

With this, as sensor rotate once, integrated value will increase by 0.5.

< Caution>

In case of 90°phase contrast input, same setting sh ould be applied to A/B input scaling data,
EXP value, and frequency divider.

Internal multiplier value

Input signal

frequency divider 1/3

Reset input

Display value

It is not clear even if reset.

P23