SHIMPO DT-601CG User Manual

Page 4

Advertising
background image

1. SUMMARY

This instrument is a Reversible integrating counter with calculation function

<Timing chart of each preset output operation>

(1) +2stages preset operation

<Boosting operation>

<Down operation>

Setting condition

OFFSET = 0 , OFFSET < PRESET A < PRESET B PRESET B = 0 , PRESET B < PRESET A < OFFSET

(2) ±Each 1stage preset operation

<Boosting/Down operation>

Setting condition

Up/Down, and Automatic reset setting will be invalid
OFFSET = 0 , OFFSET < 0 , PRESET B < OFFSET < PRESET A

<No automatic reset> <With automatic reset>

n = Minimum count

(Display)

(Continuous)

without
re-output

with
re-output

n = Minimum count

(Display)

<No automatic reset> <With automatic reset>

(Continuous)

(Continuous)

(Continuous)

n = Minimum count

(Display)

without
re-output

with
re-output

(Continuous)

(Continuous)

OFFSET

PRESET A+n

PRESET A

PRESET B+n

PRESET B 0

OFFSET

PRESET B+n

PRESET A

PRESET A-n

OFFSET 0

PRESET A

PRESET A-n

OFFSET 0

PRESET B+n

PRESET B 0

P2