SHIMPO DT-601CG User Manual
Page 21

3. Mode content and set value
Setting of display selection, measurement calculation, decimal position of display 1
and decimal position of display 2
0 0
A
B
C
D
E
F
0
0.
0
0
0
0
Display 2 decimal point position
0 :
0
1 :
0.0
2 :
0.00
3 :
0.000
Display 1 decimal point position
0 :
0
1 :
0.0
2 :
0.00
3 :
0.000
Measurement calculation method
No.
0
1
2
3
4
5
6
* Choose from 90°phase contrast input (RE)type, "0" or "3"
Display selection
0: Display 1 (fixed)
1: Display 2 (fixed)
2: Display 1/ Display 2 (selectable)
<Display selection>
Select from switching display or keeping it as fixed when pressing ENT key
on the measurement display.
<Measurement calculation method>
<Decimal point position>
Setting the display digits which are after the decimal point.
Add the signal which was entered to A input when B input was in LOW level
and deduct the signal which was entered to A input when B input was in HI level.
A - B
A + B
A or - A
Add the signal which was entered to A input and deduct the signal
which was entered to B input.
Add the signals which were entered to A and B input
Add the signal which was entered to A input
Deduct the signal which was entered to A input
Add the signal which was entered to B input
Deduct the signal which was entered to B input
A
- A
B
- B
A
-B
- A
-B
A - B
B
A
B
A + B
A
A or -A
-----
Mode#
Display 1
Display 2
A - B
A
P19