SHIMPO DT-601CG User Manual

Page 27

Advertising
background image

Mode#

Alarm output: Setting of alarm output 1 (OUT 1-4)

0 5

* Model with optional line receiver input(L1,L2) cannot output as output terminal will be input

terminal <only LED can react>

A

B

C

D

E

F

0

5.

0

0

Selection of preset action

0 : plus side 2 stages preset action
1 : ±each stage preset action
2 : batch count action (only the setting with automatic reset)
3 : plus 1 stage and secondary output action

(only the setting without re-output)

Display selection

0 : Display 1
1 : Display 2

<Caution>

Do not select display 2 when selecting A or -A with Mode 00 [measurement calculation method]

[Display selection]

Display 1 : Output against Display 1
Display 2 : Output against Display 2

[Preset action selection]

setting of output action
For the timing chart and setting condition,
refer to [output timing for preset action and setting condition]

* when changing setting, do so as display offset value

and preset value will be included in setting condition.

<Caution>
When Mode 05 to 07 are changed, DO NOT FORGET TO RESET BEFORE STARTING MEASURING.

P25