Output timing for preset action and setting condition
2: Batch count action
<Up Action>
<Down Action>
With this preset action, display will show batch count while pressing "Shift Key"
Setting item (Contents)
Preset A: Setting value of No.1 counter Preset B: setting value of batch count display
Offset: Reset display value (display offset setting value)
Setting condition (set each item as follow)
UP: offset=0, Offset < Preset A, Preset B > 0
DOWN: Preset3=0 Offset > Preset A, Preset B >0
3: Plus 1stage and secondary output action
<Up Action>
<Down Action>
Setting item (Contents)
Preset A: Pulse setting value Preset B : Retardation setting value
Offset: Reset display value (display offset setting value)
Setting condition (set each item as follow)
UP: offset=0, Offset < Preset A, 99.9
≥
Preset B
≥
0
DOWN: Preset3=0 Offset > Preset A, 99.9
≥
Preset B
≥
0
<Without automatic reset> <With automatic reset>
<Without automatic reset> <With automatic reset>