SHIMPO DT-601CG User Manual
Page 32

Mode#
Output alarm: setting of output alarm 3 (OUT1-4)
0 7
A
B
C
D
E
F
0
7.
1
3
1
3
OUT 2&4 Duration of 1shot output
0 :
10 ms
5 :
250 ms
1 :
20 ms
6 :
500 ms
2 :
50 ms
7 :
750 ms
3 :
100 ms
8 :
1 sec
4 :
200 ms
9 :
2 sec
<Caution>
Output 2&4's LED flashing might not be visible when 10ms
is chosen although
Out 2&4 Output mode
0 : sequence output
1 : 1shot output
OUT 1&3 Duration of 1shot output
0 :
10 ms
5 :
250 ms
1 :
20 ms
6 :
500 ms
2 :
50 ms
7 :
750 ms
3 :
100 ms
8 :
1 sec
4 :
200 ms
9 :
2 sec
<Caution>
Output 1&3's LED flashing might not be visible when 10ms
is chosen although
Out 1&3 Output mode
0 : sequence output
1 : 1shot output
[ OUT1&3 or OUT 2&4 output mode]
Sequence :
Output will be activated when the conditions are met.
If it is beyound tolerance (condition), output will be OFF.
1 shot :
1 shot of pulse with set duration will be output when output conditions are met.
[ OUT 1&3 or OUT 2&4 duration of 1shot output]
Set the duration of 1shot output. (output margin is ±2ms)
P30