7

Series 5800 5800_IOM_RevB_0413

Flow direction is reversed when used with Cylinder Actuator Failed

BODY PrESSUrE-TEMPErATUrE rATINgS:

Temperature

(F)

150

FLg

Steel

300

NPT, SWE,

or FLg Steel

150

FLg

St Steel

300

NPT, SWE,

or

FLg St Steel

+32° To 100°F

285

740

275

720

150°

272

710

255

670

175°

266

695

245

645

200°

260

680

235

620

225°

252

673

230

605

250°

245

667

225

590

275°

237

661

220

575

300°

230

655

215

560

325°

222

650

210

548

350°

215

645

205

537

375°

207

640

200

526

400°

200

635

195

515

450°

185

620

182

497

500°

170

605

170

480

550°

155

587

155

465

600°

140

570

140

450

650°

125

550

125

440

700°

110

530

110

435

750°

95

505

95

425

800°

80

410

80

420

Body Pressure — Temperature Ratings conform to ANSI based on body/

flange rating and body material. As the fluid temperature increases, the

maximum allowable internal pressure decreases. Verify maximum pressures

and temperatures prior to selecting body material and body/flange rating.

NOTE: Approaching limits for
continuous use will reduce trim
life. For continuous use, stay
within half of rated maximum.

NOTE ON BEARINGS: PEEK
Bearings should not be used
for temperatures above

450ºF or flowing differential
pressure above 300 PSIG.

TrIM MATErIALS

FLOWINg

DIFFErENTIAL

PrESSUrE LIMIT

316 Stainless Steel

100 PSID

TFE

100 PSID

PEEK

100 PSID

400 Stainless Steel

200 PSID

Alloy 6

300 PSID

ShUT-OFF (ALLOWABLE SEAT LEAkAgE) CLASSES

Leakage
Class

Maximum Seat Leakage

Test
Fluid

Test
Pressure

relative
Seat
Tightness

Class II

0.5% of rated CV

Water 45 to 60 PSI

1

Class III

0.1% of rated CV

Water 45 to 60 PSI

5

Class IV** 0.01% of rated CV

Water 45 to 60 PSI

50

Class V

0.0005 ml /min/inch
of trim size/ ∆P(PSI)

Water Max Operating ∆P 300,000

Class VI** Class VI about 0.9 ml/min * Air

50 PSI

600,000

* Leakage rate varies by valve size, Refer to the ANSI/FCI Standard
70.2.
**Class IV and V are the ONLY leakage classes available within the
5800 Series.

Pressure ratings are PSIG
For applications below 32° consult factory