Input Power Connections

Risk of electric shock – cord connected models are supplied with a grounding
conductor and grounding-type attachment plug. To reduce risk of electric shock, be
certain that it is connected only to a properly grounded, grounding-type receptacle.

Three power cord plug types available.

Power cord length is 6 feet (3.83 meters)

WARNING

!

Be certain to connect pump to proper supply voltage. Using incorrect voltage will damage pump and may result in

injury. Voltage requirement is printed on pump serial label.

!

Input power range is 96VAC to 264VAC 50/60 Hz.

!

Voltage Selection is automatically detected and adjusted by power supply. No mechanical switch necessary.

!

Use voltage your power cord is rated for.

!

Cord connected models are supplied with a ground wire conductor and a grounding type attachment plug (power

cord). To reduce risk of electric shock, be certain that power cord is connected only to a properly grounded,
grounding type receptacle.

!

Permanently connected models must be properly grounded. Be certain that a grounding conductor is connected

to terminal T11-1 located in the wiring compartment.

!

Never strap control (input / output) cables and power cables together.

!

Power Interruption: This pump has an auto-restart feature which will restore pump to operating state it was in

when power was lost.

Note: When in doubt regarding your electrical installation, contact a licensed electrician.

Electrical connections and grounding (earthing) must conform to local wiring codes.
Be certain that a grounding conductor is connected to terminal T11-1 located in the
wiring compartment.

WARNING

115V 60Hz
NEMA 5/15 (USA)
max: 125V AC

230V 60Hz
NEMA 6/15 (USA)
max: 250V AC

240V 50Hz
CEE 7/VII (EU)
max: 250V AC

QTY. DESCRIPTION

2

.50 INCH (12.7 mm) LIQ-TIGHT HOLE PLUGS (MAT’L = NEOPRENE), PRE-INSTALLED

3

.875 INCH (22.2 mm) LIQ-TIGHT HOLE PLUGS (MAT’L = NEOPRENE), 2 PRE-INSTALLED

2

.50 INCH (12.7 mm) LIQ-TIGHT CONNECTORS FOR PASS THRU CORDS (MAT’L = NYLON)
ACCEPTABLE CABLE DIAMETER .118 TO .255 INCH (3.0 TO 6.5 MM), NOT INSTALLED

3

.875 INCH (22.2 mm) METALLIC LIQ-TIGHT CONNECTORS FOR PASS THRU CORDS (MAT’L = NYLON)
ACCEPTABLE CABLE DIAMETER .200 TO .395 INCH (5.1 TO =10.0 MM), 1 PRE-INSTALLED WITH POWER CORD MODELS

Cable and conduit connectors included

5.99 in.

(152.1 mm)

Ø
(12.7 mm)
2-PLCS.

.50

Ø
(21.3 mm)
3-PLCS.

.84 in.

WIRING COMPARTMENT COVER

POWER CORD OPTIONS

Risk of electric shock - Disconnect electricity before removing the wiring
compartment cover.

WARNING

Flex-Pro

2

METALLIC LIQ-TIGHT CONNECTORS FOR .50 INCH FLEXIBLE CONDUIT (MAT’L = DIE CAST ZINC), NOT INSTALLED

Risk of electric shock - All
wiring must be insulated
and rated 300V minimum.