C-1700N

C-1700N

FIG. 4.2 TYPICAL INSTALLATION

Page 4

Page 5

Discharge

Tube

Pumping unit

Chemical
# 1

¼" & ½" NPT Injector

C-1700N

4-1/2”

9-1/16”

7-5/32”

FIG. 4.0 DIMENSIONAL DRAWING

FIG. 4.1 INJECTOR WALL MOUNTING

4.2

Electrical Connections

4.2.1

Input Power Connections

Note: When in doubt regarding your electrical installation, contact a licensed electrician.

The C-1700N is supplied with either a ground wire conductor and a grounding type attachment plug
(power cord) or a junction box for field wiring.

POWER CORD MODELS -To reduce the risk of electric shock, be certain that the power cord is
connected only to a properly grounded, grounding type receptacle.

JUNCTION BOX MODELS -To reduce the risk of electric shock, be certain that a grounding conduc-
tor is connected to the green grounding conductor located in the junction box.

FIG. 4.4 WIRING DIAGRAM - STANDARD MODELS

AC
MOTOR

INPUT

VOLTAGE

115V 60Hz

HOT

LEADWIRE

NEUTRAL

LEADWIRE

GROUND

LEADWIRE

230V 60Hz

BLUE or YELLOW

BLUE

BROWN

RED

GREEN

GREEN

GREEN

MOTOR LEADWIRES

Neutral

Hot

Ground (green)

Earth Ground (green)

Common

Hot

AC

Input

Power

220V 50Hz

BLACK or YELLOW

BLACK or YELLOW

* Yellow leadwire : thermally protected motor
Black or Blue leadwire: standard impedance protected motor

*

*

*

24V 60Hz

WHITE

GREEN

BLUE

*

#10 Self-Tap
(2 X)

2.30”

Slide in

Clamp
Wall Mount

Chemical
# 2

¼" & ½" NPT Injector

Discharge

Tube

Suction

Tube

Suction

Tube

Risk of chemical overdose. Be certain the pump does not
overdose chemical during backwash and periods of no flow in
the circulation system.

!

WARNING

To prevent chemical overdosing, a flow switch is recommended
on the circulation system to automatically stop chemical feed
when there is no return flow to the swimming pool or spa.

!

CAUTION

SHOCK

!

WARNING

Risk of electric shock.

Be certain to connect the pump to the proper

supply voltage. Using the incorrect voltage will damage the pump and
may result in injury. The voltage requirement is printed on the pump
serial label.

To prevent chemical overdosing, disconnecting power to the
circulation system must also disconnect power to the pump.

!

CAUTION