Shut-off and check valves

The shut-off valves are equipped with a built-in check valve,

positioned inside the ball.

1. To allow the passage of the fluid

in both directions, the ball valves

must be opened at 45°, using a

9 mm fixed wrench.

The check valve is opened by the

ball, see figure (A).

2. In normal system operation, the

ball valves must be completely

open.

Air separator device

The solar circulation units with flow and return connection are

equipped with an air separator device on the flow line. The gases

separated from the thermal carrier medium collect at the top of the

deaerator.

The collected gases must be evacuated from time to time (every

day after commissioning and afterwards, depending on the

quantity of air, once a week or once a month) using the manual air

vent with a suitably sized screwdriver.

To maintain optimal efficiency of the solar thermal system,

afterwards, it is necessary to

vent the system every six

months by using the deaerator.

A

Full closing and opening of the valve

The

valve

can

be

completely opened or

closed.

A slot on the obturator

stem

indicates

the

status of the valve.

Correction for liquids with different density

The variation in the flow rate reading remains within the range of

accuracy indicated (±10%), for glycol percentages up to 50%.

Fully closed

Fully open

7

Captive nut

Flow rate adjustment

Fitting 1/2” F

Graduation

Fitting 3/4” F

Flow meter

The flow meter is a floating gauge flow rate measurator with a

built-in regulating ball valve.

It works within the range of 1–13 l/min.

The flow meter must be fitted in a vertical position only.

A thermometric label is placed on the back of the flow meter to

signal if the maximum permitted temperature (110°C) has been

exceeded:

white color = temperature not exceeded;

dark color = maximum temperature exceeded.

The label removal makes the manifacturer warranty on the device

expire.

The level is taken from the

top edge of the float.

N.B! Use only a 9mm fixed

wrench to regulate the flow

meter.

13

11

9

7

open

closed

23

0

°F

110

°C

Thermometric

label

A

B