SPECIFICATIONS
Range:
RH: 0 to 99.99%; Temperature: -4 to 122°F (-20 to 50°C).
Accuracy: ±3% @ 25°C/10 to 90% RH (±5% @ 0 to 10%, 90 to 100%) ±1°F
(0.6°C).
Display: 4-digit LCD.
Resolution: 0.1°F/°C.
Power Requirements: One CR-2032 lithium battery.
Weight: 3.2 oz (91 g).
Agency Approvals: CE.

The Model TH2-10 Thermo-Hygrometer Pen is a compact handheld device that
measures temperature, humidity, dew point, wet bulb, and heat index. For
increased accuracy, calibration salt baths can be used to field calibrate the
humidity sensor before taking measurements. Minimum, maximum, and average
readings can be displayed on the large 4 digit LCD display. High and Low alarms
provide audible and visual indication of changes to the ambient humidity.

FEATURES
1) Temperature and relative humidity measurement.
2) Calculate dew point temperature and wet bulb temperature.
3) Calculate heat index and wet bulb global temperature.
4) Hi Temperature alarm setting (Heat Index/WBGT).
5) Data hold & Maximum/Minimum/Average function.
6) Auto power off function.
7) Self-calibration by salt bottle (Optional) at 33% & 75% humidity points.
8) Quick response and high accuracy.

OPERATING INSTRUCTIONS
Please read the manual completely before using this device.

KEY FUNCTION
(1) PWR: Turn on / off the meter.
(2) HOLD: Data hold mode.
(3) MODE: Select measurement modes: Temp. (temperature), RH (Relative
Humidity), HI (heat index), DP (dew point), WB (wet bulb), HI WB (wet bulb global
temperature / WGBT).

OPERATION
Power On/Off
Press the POWER button to turn on the meter. The meter will display TEMP
reading and icon with a beep sound. To turn off the meter, press the POWER
button for more than 2 seconds.

Maximum and Minimum Mode
With the meter already on, press the POWER button less than 2 seconds. The
MAX icon with the highest reading appears on the LCD. Press the POWER button

again and the MIN icon will appear with the lowest reading on the LCD. Press the
POWER button again and the AVG icon appears with the average reading on the
LCD. Press POWER again and the meter will return to normal measurement.

1-3/8

[35.05]

5-9/16

[141.38]

45/64

[18.01]

2-5/8

[65.34]

2-5/8

[65.34]

2

[52.32]

2

[52.32]

BATTERY COMPARTMENT

TH2-10

33% SALT SOLUTION

SALT SOLUTON KIT

TH2-CAL

75% SALT SOLUTION

15ºC
20ºC
25ºC
30ºC
35ºC

15ºC
20ºC
25ºC
30ºC
35ºC

xxxx±xxx
xxxx±xxx
xxxx±xxx
xxxx±xxx
xxxx±xxx

Made in xxxx

33%RH Mgcl
Sat. salt solution
Temp. Mgcl

75%RH Mgcl
Sat. salt solution
Temp. Mgcl

xxxx±xxx
xxxx±xxx
xxxx±xxx
xxxx±xxx
xxxx±xxx

Made in xxxx

S/N: xxxxxxxx

Battery:

Made in xxxxxx

AAA (UM-4)
CR2032
gVoltage

Thermo-Hygrometer

Power

Hold

Mode

(HI. WBGT TH2-10)

DATA HOLD
Press the HOLD button to freeze readings. Press the HOLD button again to return
to normal measurement.

Auto Power Off
The meter will shut off automatically after approximately 15 minutes of no action.
To disable auto power off, press the HOLD and POWER button at the same time
until “S-no” appears. Then release the button and you will return to normal
measurement.

Once the meter is powered off, it will return to the default auto power off settings.

SELECT TEMP UNIT °C/°F

SETTING MODE- ALARM SETTING (AFTER SELECTING TEMP UNIT °C/°F)

Note:
1. The alarm sound can’t be disabled unless you enter setting mode to change the
threshold setting.
2. The default settings of Heat Index and WBGT alarm settings are off.
3. Please go through and select Temp. unit (C/F) before alarm setting.

When Power off,
press MODE+POWER to enter setting function
Press MODE button to select °C/°F
Press POWER button again to save and move to
next setting.
NOTE: (a) During set operation, if you want to
escape any mode setting, please go through all
setting modes by keeping press POWER button to
normal measurement.
(b) If you want to set alarm threshold, please follow
steps below.

Advertising