Back Panel I/O and Labeling


Each back panel has terminal blocks used for I/O with special laser markings depending on
the cards installed in the rack. The half rack has one 12 position terminal block, the 3/4 and

full racks have two 12 position terminal blocks. The outputs are labeled to be consistent with
the table below where `x' refers to the channel number. Unfortunately, because of the density

of the outputs on the back plane vs. the available outputs on the terminal blocks all outputs
will not always be available on the terminal block. If you need a specific output not provided
on the back panel terminal block please call the factory for information. If you have a function

card not listed here please refer to the manual for the specific function card on terminal block
labeling information.


TB
Module label

Function

8200

CHx

Signal out of measuring channel

GND

Ground from measuring channel

8200HT

CHx

Signal out of measuring channel

GND

Ground from measuring channel

VC8000

+Ix

Hi side current out of measuring channel

-Ix

Lo side current out of measuring channel

SP8000

SHx

Hi set point OC output for CHx

SLx

Lo set point OC output for CHx

CEx

common emitter output for CHx setpoints

GHx

Go set point high for CHx

GLx

Go set point low for CHx

SC8000 x+/-x

Summed

Output

SHx

Hi set point output for CHx

SLx

Lo set point output for CHx

CEx

common emitter output for CHx

DY8000

PPX

Peak-to-Peak or Positive peak for CHx

NPX

Negative Peak for CHx

RMx

RMS for CHx

SHx

Hi set point output for CHx

SLx

Lo set point output for CHx

CEx

common emitter output for CHx

Any

GND

Ground

+V

+15 volt from internal supply or +15V input

-V

-15 volt from internal supply or -15V input

Table 3 -- Terminal Block Labeling;