Rail – NORSTAT Non-Contact Safety Switches User Manual

Page 2

Advertising
background image

SAFETY CONTROL UNIT

SAFETY SWITCHES

Mounting on 35mm DIN

Rail

Mounting the Safety Switches

Removal from 35mm DIN

Rail

Indication

CONTROL UNIT RESET

POWER

When power is

connected, the red

LED will be

illuminated

OUTPUT

When K1 & K2 are

illuminated green,

the outputs 13/14

& 23/24 will be

closed and 31/32

will open.

Internal switch is set to the

LOWER position

Circuit X1/X2 requires a

momentary N/O button to

initialise reset.

Internal switch is set to the

UPPER position

Circuit X1/X2 requires a link.

NOTE: Closed contacts on

K3 & K4 can still be moni-

tored

To remove lid, use small screwdriver in the lid recess as

shown and prise gently upwards.

Manual Reset

Automatic Reset

1

2

1

2

The control modules are de-

signed to be mounted in an IP55

(minimum) control cabinet.

The modules clip on to standard

35 mm symmetric DIN-Rail

To remove the modules, gently

lever out the DIN clip with a

small screwdriver as shown (1).

Tilt the unit in the direction (2)

and slip the unit off the DIN Rail

Minimum separation 50mm

between adjacent switches.

Do not use

safety switches

as a stop.

1 mm separation

when closed

provides the best

results.

DO NOT mount

on hinged side of

the guard.

EN1088 :

Hide the actuator where

possible.

50

mm

Minimum Gap

A

A

A

S

S

S

A

S

A
S

NORSTAT INC. 300 Roundhill Dr. Rockaway, NJ 07866