INSTALLATION INSTRUCTIONS

‘‘OLA’’ Series

INSTALLATION
1. Remove heater front panel and upper front grille for heater with

front hot air exit to give access to junction box covers and

fastening

holes.

2. Remove the appropriate knockout and run the electrical wiring
through

it.

3. Attach heater to the wall by using the 1/4 in. (6.4 mm)

knockouts and the angle bracket.

4. Remove the junction box covers. Make connections according

to local and national codes. See wiring diagrams.

5. Replace all covers before energizing.

HEATER INTERCONNECTION
The connection boxes and the wiring channel of this series heater
and options corners and control box are approved for
interconnexion of heaters and components which are on the same
heating branch circuit. Grounding wire must join the ground lugs
of all heaters.

For all other options of this series, use «BX» cable
or «EMT» tubing.

MAINTENANCE
Once a year, remove the front panel and use a vacuum
cleaner to remove the dust accumulation inside the heater.
Cleaning should be done while the heater is disconnected
from the supply circuit.

Any other servicing should be performed by a qualifi ed
technician.

ATTENTION
Basic precautions should always be followed to reduce the
risk of fi re, electric shock, and injury to persons.
- Read all instructions before using this heater.
- This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. Keep combustible
materials, such as furniture, pillows, bedding, papers,
clothes, and curtains at least 12 in. (305 mm) from the
front and the top of the heater.
- Do not use outdoors.
- Do not insert or allow foreign objects to enter any
ventilation or exhaust opening as this may cause an
electric shock or fi re, or damage the heater.
- To prevent a possible fi re, do not block air intakes or
exhaust in any manner.
- Heater has contains arcing and sparking parts. Do not
use it in areas where gasoline, paint, or fl ammable
liquids are used or stored.
- Use this heater only as described in this manual. Any
other use not recommended by the manufacturer may
cause

fi re, electric shock, or injury to persons.

WARRANTY

OUELLET CANADA INC. warrants the electric heating
element of the OLA series for a one (1) year period; and their
component parts againts defects in material and workmanship
for one (1) year period following the date of purchase, under
normal use and service, when proof of purchase of such is
provided to the manufacturer. The obligation of Ouellet
Canada Inc., under the terms of this warranty, will be to
supply a new unit and this omits the manufacturer to bear
the installation costs or other secondary charges linked to
replacing the unit or component part(s).

KEEP THIS INSTRUCTION PAMPHLET FOR THE

USER - INS104-200311-03

JUNCTION BOX VOLUME
287 in.

3

(4700 cm

3

)

CONTROL OPTIONS
See instructions included with option.

ACCESSORIES
See instructions included with accessories.

EMPTY CABINET INSTALLATION
Empty cabinets are installed the same way as complete heaters.

BUILT-IN THERMOSTAT SETTING (option)
The built-in thermostat can be set with a small fl at screwdriver
through the upper grille.

To set the thermostat at the desired temperature :
- Set thermostat at maximum temperature (turn clockwise).
- When the desired temperature is reached, turn the thermostat
counter-clockwise slowly until you hear a «click».
- The thermostat will keep the room at this temperature.

KOE ł28-ł22

KOE ł1 1/8-ł7/8

204

8

152

6

51

2

KOE ł28-ł22

KOE ł1 1/8-ł7/8

51

2

132

5 3/16

512

20

64

2 1/2

KOE 102 X 52

KOE 4 X 2

184

7 1/4

317

12 1/2

215

8 1/2

KOE ł6.4

KOE ł1/4

KOE ł22

KOE ł7/8

Not recessable with grill on top

Recessable with grill on front (-FR)

76

3

51

2

58

2 1/4

KOE ł6.4

KOE ł1/4

Bottom view

Right side

view

DIMENSIONS

mm

inches

THE INSTALLATION MUST BE EXECUTED

BY A QUALIFIED TECHNICIAN

RISK OF ELECTROCUTION

IMPORTANT

Allow 12 in. (305 mm) minimum clearance

from the front and the top of the heater.

CAUTION

NON-RESIDENTIAL USE IN THE UNITED STATES

Advertising