PEP Filters HMF2 User Manual

Page 14

Advertising
background image


HMF2 Series Filter System

Operating & Maintenance Manual

PEP Filters

• 322 Rolling Hill Road • Mooresville, NC 28117 • 800-243-4583 •

www.pepfilters.com

14 of 19

Rev. 041204

Table 1 Inspection Chart
PART HMF

MODEL

Filter Tank

X

Valves & Linkage

X

Filter Inter-connection Piping

X

Pump Pre-strainer tank & basket

X

Pump

X

NEMA 4X Box (Auto only)

X

Filter Skid

X

Pressure gauge, air relief valves, & tees

X

Media (shipped Loose)

X

Table 2 Connection Sizes

System Water Backwash

City Water

Backwash

HMF2

Model

Pump Inlet

Filter Outlet

Waste Outlet

Inlet City Water

HMF

Inches/mm

12 2/50.8

1/25.4

1/25.4

1/25.4

18 2/50.8

2/50.8

2/50.8

2/50.8

24 2/50.8

2/50.8

2/50.8

2/50.8

30 2.5/63.5

2/50.8

2/50.8

2/50.8

36 2.5/63.5

3/76.2

3/76.2

3/76.2

42 3/76.2

3/76.2

3/76.2

3/76.2

48 3/76.2

3/76.2

3/76.2

3/76.2

Table 3 Filter Flow Rates

HMF2

Model

Forward Flow

gpm / lps

Minimum Backwash Flow Rate

gpm / lps

Maximum Backwash Flow Rate

gpm/lps

12 16/.96

12.8/.78

16/.96

18 35/2.2

28/1.8

35/2.2

24 63/3.8

47/3.0

63/3.8

30 98/6.2

74/4.6

98/6.2

36 141/4.0

107/6.7

141/4.0

42 192/13.0

144/9.1

192/13.0

48 251/15.8

188/11.9

251/15.8

Table 4 Electrical Requirements (1

φ, 60 Hz.)

PUMP HP/KW

Voltage 1

φ 60/50HZ

Full Load Current

(Amps)

1/0.75

110, 208, 240

16, 8.8, 8

2/1.5

115, 208, 230

24, 13.2, 12

3/2.25

208, 230

18.7, 17

Advertising