Specifications, Characteristics & requirements, Table 3-1: performance characteristics – PNI SeaTRAX User Manual

Page 8: 3specifications, 1 characteristics & requirements

Advertising
background image

PNI Sensor Corporation

DOC#1018154 r02

SeaTRAX User Manual

Page 3

3

Specifications

3.1

Characteristics & Requirements

Table 3-1: Performance Characteristics

1

Parameter

Value

Heading

Accuracy

≤65° of pitch after full range calibration <0.3° rms
≤80° of pitch

after full range calibration <0.5° rms

≤5° of pitch after 2D calibration

<2.0° rms

≤2 times the calibration tilt angle when
using limited-tilt calibration

2

<2.0° rms

Resolution

0.1°

Repeatability

0.05° rms

Attitude

Range

Pitch

± 90°

Roll

± 180°

Accuracy

Pitch

0.2° rms

Roll

≤65° of pitch

0.2° rms

≤80° of pitch

0.4° rms

≤86° of pitch

1.0° rms

Resolution

0.01°

Repeatability

0.05° rms

Maximum Operational Dip Angle

3

85°

Magnetometers

Calibrated Field Range

± 125 µT

Resolution

0.05 µT

Repeatability

± 0.1 µT

Footnotes:

1. Specifications are subject to change. Assumes the SeaTRAX is motionless and the local

magnetic field is clean relative to the user calibration.

2. For example, if the calibration was performed over ±10° of tilt, then the SeaTRAX would provide

<2° rms accuracy over ±20° of tilt.

3. Performance at maximum operational dip angle will be somewhat degraded.

Advertising