MAINTENANCE

86037390 02/14/07

4-13

PROBLEM CAUSE SOLUTION

External leak in chemical piping

Tighten fittings. Re-apply thread sealant
where required. If any fittings are
damaged, replace.

Outlet check valve is full of debris
or damaged, not allowing it to close
properly

Close the chemical valve on the instrument
panel. If the flow meter does not indicate
flow, remove debris or replace check valve,
if necessary.

Chemical pump diaphragm is
ruptured

Close the chemical valve on the instrument
panel. If the flow meter still indicates flow,
replace the chemical pump diaphragm.

Chemical flow meter indicates
flow with the tool valve closed

Internal leak in chemical valve
causing continual flow through
prime tube returning to container.

Tighten valve packing nut (see “General
Service Adjustments” section in this
manual). Replace valve, if necessary.

Main circuit breaker on the control
panel has been tripped.

After inspecting the unit to determine the
cause of the tripped circuit breaker, press
the reset button.

Loose or corroded battery.

Clean, tighten, or replace the battery
terminals.

Dead battery.

Recharge or replace battery.

Defective ignition switch.

Test ignition switch for power going into the
switch. If there is power going in but NO
power going out, replace the switch.

Defective starter motor.

Test the starter motor. If necessary replace.

Engine will not start

The engine does not turn over

Vacuum pump seized.

Refer to Gardner Denver Service & Repair
Manual.

Waste tank is full.

Empty the waste tank.

Defective fuel pump.

Replace the fuel pump.

Loose or broken wires leading to
waste tank float switch.

Repair or replace any broken electrical
connections.

Defective float switch in the waste
tank.

Check switch for proper operation, replace
as necessary.

Starter turns over engine, but
will not start

Internal engine problem.

Consult the Briggs & Stratton Vanguard
Service And Repair Instruction Manual or
contact your local Briggs & Stratton
authorized repair center.

Advertising